Reproducibility of retinal nerve fiber layer thickness measurements using scanning laser polarimetry in pseudophakic eyes.

机译:在伪晶状体眼中使用扫描激光偏振法测量视网膜神经纤维层厚度的可重复性。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: To assess the reproducibility of retinal nerve fiber layer measurements in pseudophakic normal and glaucomatous eyes using scanning laser polarimetry (GDx, Laser Diagnostic Technologies, Inc., San Diego, CA). PATIENTS AND METHODS: Normal and glaucomatous patients with polymethylmethacrylate posterior chamber intraocular lenses that satisfied entry criteria underwent imaging by two experienced operators. Eyes with posterior capsule opacification or vision less than 20/30 were excluded. Baseline images (mean pixel SD less than 8 mm) were obtained on 3 separate days within a 7-week period. Reproducibility, defined as the pooled within eye variance of these 3 measurements and the coefficient of variation for 12 retardation parameters generated by GDx software were calculated. RESULTS: Eighteen eyes (11 glaucoma, 7 normal) of 15 patients (7 female, 8 male) were enrolled (mean age 78 +/- 6 years). Among glaucomatous eyes, the average mean deviation and corrected pattern standard deviation using achromatic automated perimetry (Zeiss-Humphrey, Dublin, CA) was -3.8 +/- 1.5 dB (range, -1.89 to -5.04 dB) and 4.9 +/- 3.3 dB (range 0 to 11.05 dB), respectively. Coefficient of variation was 10% or less for all retardation parameters except ellipse modulation (20.2%) and neural network number (12.4%). Glaucomatous and normal eyes had similar variability for 8 of 12 (66.7%) retardation parameters. Inferior ratio, ellipse modulation, and superior ratio were significantly less variable in glaucomatous eyes (P = 0.007, 0.02, and 0.04 respectively) than normal eyes. Superior integral was more variable in glaucomatous eyes (P = 0.03). CONCLUSION: Retardation measurements may be obtained in pseudophakic eyes with acceptable reproducibility. Normal eyes and eyes with mild glaucomatous damage have similar variability for most retardation parameters.
机译:目的:使用扫描激光偏振仪(GDx,激光诊断技术有限公司,加利福尼亚州圣地亚哥)评估假晶状体正常眼和青光眼中视网膜神经纤维层测量的可重复性。患者和方法:两名经验丰富的操作者对满足入院标准的聚甲基丙烯酸甲酯后房型人工晶状体的正常和青光眼患者进行了成像。后囊混浊或视力小于20/30的眼睛被排除在外。在7周内的3天中分别获得了基线图像(平均像素SD小于8毫米)。计算了可重复性,定义为这3次测量的眼动范围内的总和,并计算了GDx软件生成的12个延迟参数的变异系数。结果:纳入15例患者(男7例,男8例)的18眼(11例青光眼,7例正常)(平均年龄78 +/- 6岁)。在青光眼中,使用消色差自动视野仪(Zeiss-Humphrey,都柏林,加利福尼亚)的平均平均偏差和校正模式标准偏差为-3.8 +/- 1.5 dB(范围为-1.89至-5.04 dB)和4.9 +/- 3.3 dB(范围从0到11.05 dB)。除椭圆调制(20.2%)和神经网络数(12.4%)外,所有延迟参数的变异系数均小于或等于10%。青光眼和正常眼对于12个延迟参数中的8个(66.7%)具有相似的变异性。在青光眼眼中,下眼比率,椭圆调制和上眼比率的变化明显小于正常眼(分别为P = 0.007、0.02和0.04)。在青光眼中,上积分更易变(P = 0.03)。结论:可在伪晶状体眼中获得延迟测量,并具有可接受的再现性。正常眼和轻度青光眼损伤的眼对于大多数延迟参数具有相似的变异性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号