首页> 外文期刊>Analytica chimica acta >A simple-potentiometric method for determination of acid and alkaline phosphatase enzymes in biological fluids and dairy products using a nitrophenylphosphate plastic membrane sensor
【24h】

A simple-potentiometric method for determination of acid and alkaline phosphatase enzymes in biological fluids and dairy products using a nitrophenylphosphate plastic membrane sensor

机译:一种简单的电位计方法,使用硝基苯基磷酸酯塑料膜传感器测定生物流体和乳制品中的酸和碱性磷酸酶

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

A novel poly(vinyl chloride) matrix membrane sensor responsive to 4-nitrophenylphosphate (4-NPP) substrate is described, characterized and used for the potentiometric assay of acid (ACP) and alkaline (ALP) phosphatase enzymes. The sensor is based on the use of the ion-association complex of 4-NPP anion with nickel(II)-bathophenanthroline cation as an electroactive material and nitrophenyloctyl ether (NPOE) as a solvent mediator. The sensor displays good selectivity and stability and demonstrates a near-Nernstian response for 4-NPP over the concentration range 9.6 x 10~(-6) to 1.0 x 10~(-2) M with an anionic slope of 28.6 ±0.3 mV decade~(-1) and a detection limit of 6.3 x 10~(-6) M over the pH range 4.5-10. The sensor is used to measure the decrease of a fixed concentration of 4-NPP substrate as a function of acid and alkaline phosphatase enzyme activities at optimized conditions of pH and temperature. A linear relationship between the initial rate of 4-NPP substrate hydrolysis and enzyme activity holds over 0.05-3.0 and 0.03-3.4 IUL~(-1) of ACP and ALP enzymes, respectively. Validation of the method by measuring the lower detection limit, range, accuracy, precision, within-day repeatability and between-day-variability reveals good performance characteristics of the proposed sensor. The sensor is used for the determination of acid and alkaline phosphatase enzyme activities in biological fluids of some patients suffering from alcoholic cirrhosis, acute myelocytic leukemia, pre-eclampsia and prostatic cancer. The sensor is also utilized for assessment of alkaline phosphatase enzyme in milk and dairy products. The results obtained agree fairly well with data obtained by the standard spectrophotometric methods.
机译:描述了一种新型的响应于4-硝基苯基磷酸酯(4-NPP)底物的聚氯乙烯基质膜传感器,其特征在于用于酸(ACP)和碱性(ALP)磷酸酶的电位测定。该传感器基于使用4-NPP阴离子与镍(II)-二苯菲咯啉阳离子作为电活性材料和硝基苯基辛基醚(NPOE)作为溶剂介体的离子缔合配合物。该传感器显示出良好的选择性和稳定性,并且在9.6 x 10〜(-6)M至1.0 x 10〜(-2)M的浓度范围内对4-NPP表现出接近能斯特的响应,阴离子斜率为28.6±0.3 mV十倍〜(-1)的检出限在pH范围4.5-10时为6.3 x 10〜(-6)M。该传感器用于测量在最佳pH和温度条件下,固定的4-NPP底物浓度随酸和碱性磷酸酶活性的变化。 4-NPP底物水解起始速率与酶活性之间的线性关系分别超过ACP和ACP酶的0.05-3.0和0.03-3.4 IUL〜(-1)。通过测量下限,范围,准确性,精确度,日内重复性和日间变化性对方法进行验证,揭示了所提出传感器的良好性能特征。该传感器用于测定某些酒精性肝硬化,急性粒细胞性白血病,先兆子痫和前列腺癌患者的生物体液中的酸性和碱性磷酸酶活性。该传感器还用于评估奶和奶制品中的碱性磷酸酶。获得的结果与通过标准分光光度法获得的数据相当吻合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号