首页> 外文期刊>Canadian journal of ophthalmology >Comparison of exophthalmos measurements: Hertel exophthalmometer versus orbital parameters in 2-dimensional computed tomography
【24h】

Comparison of exophthalmos measurements: Hertel exophthalmometer versus orbital parameters in 2-dimensional computed tomography

机译:低渗疗法测量比较:二维计算断层扫描中的Hertel远散疗法与轨道参数

获取原文
获取原文并翻译 | 示例
           

摘要

ObjectiveTo compare the reliability of orbital parameters calculated using 2-dimensional computed tomography (CT) and Hertel exophthalmometry when measuring exophthalmos in normal subjects and in patients with thyroid-associated orbitopathy (TAO). DesignRetrospective, observational case series. ParticipantsCT images of 33 normal orbits and 69 orbits with TAO were included. MethodsIn central axial CT scans, globe area (GA), orbital area (OA), and GA/OA ratio were calculated by 2 observers using ImageJ. Interobserver agreement was analyzed for Hertel exophthalmometer and CT parameters. In patients with TAO, the association with activity and severity of TAO were also evaluated. ResultsGA and the GA/OA ratio measurements showed excellent interobserver agreement, whereas OA and the Hertel exophthalmometry measurements showed moderate agreement between the 2 observers. GA and the GA/OA ratio were significantly correlated with Hertel exophthalmometry measurements (r = ?0.740, r = ?0.706, respectively; allp< 0.001). GA and the GA/OA ratio were significantly correlated with the activity and severity of TAO (allp< 0.01). ConclusionsGA and the GA/OA ratio were reliable CT parameters with a high intraclass correlation coefficient compared with Hertel exophthalmometer.
机译:ObjectiveTo比较使用二维计算断层扫描(CT)和Hertel微散疗法计算的轨道参数的可靠性在测量正常受试者中和甲状腺相关胰疗法(TAO)的患者中。 DesignRetrospive,观察盒系列。包括33个正常轨道的参与者图像和具有陶器的69个轨道。方法中央轴向CT扫描,全球区域(GA),轨道区域(OA)和GA / OA比率使用ImageJ的2个观察者计算。 Interobserver协议被分析为Hertel Exophthalomometer和CT参数。在陶氏患者中,还评估了陶氏活性和严重程度的关系。结果和GA / OA比率测量显示出优异的Interobserver协议,而OA和Hertel远外测量测量显示在2个观察者之间显示中等协议。 Ga和Ga / OA比例与Hertel次幂术测量显着相关(r = 0.740,r = 0.706分别; allp <0.001)。 Ga和Ga / OA比与TaO的活性和严重程度显着相关(allp <0.01)。结论与Hertel远外计量相比,GA / OA比率是具有高脑相关系数的可靠CT参数。

著录项

  • 来源
    《Canadian journal of ophthalmology》 |2018年第4期|共7页
  • 作者

    Kyung Jun Choi; Min Joung Lee;

  • 作者单位

    Department of Ophthalmology Hallym University Sacred Heart Hospital Hallym University College of;

    Department of Ophthalmology Hallym University Sacred Heart Hospital Hallym University College of;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 眼科学;