首页> 外文期刊>Cornea >Evaluation of central corneal thickness measurement with RTVue spectral domain optical coherence tomography in normal subjects.
【24h】

Evaluation of central corneal thickness measurement with RTVue spectral domain optical coherence tomography in normal subjects.

机译:在正常受试者中使用RTVue光谱域光学相干断层扫描技术评估中央角膜厚度。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To determine (1) repeatability of central corneal thickness (CCT) measurements by spectral domain optical coherence tomography (RTVue; Optovue, Inc, Fremont, CA) and (2) agreement between CCT measurements by RTVue and those by ultrasonic pachymetry, Orbscan, and anterior segment optical coherence tomography (ASOCT). METHODS: In a prospective observational study, 2 cohorts of normal subjects were recruited. In the first cohort (51 subjects), 5 measurements of CCT were obtained by RTVue during the same visit to determine the repeatability. In the second cohort (65 subjects), CCT measurements were obtained by RTVue, ultrasonic pachymetry, Orbscan, and ASOCT during the same visit to determine the agreement among these instruments. Repeatability was assessed by intraclass correlation coefficient (ICC), within-subject standard deviation, coefficient of repeatability, and within-subject coefficient of variation. Agreement was assessed by ICC and Bland and Altman plots. RESULTS: Repeatability of CCT measurements by RTVue as assessed by ICC, within-subject standard deviation, coefficient of repeatability, and within-subject coefficient of variation was 0.99 (0.99-0.99), 2.2 (1.9-2.5), 4.2 mum (3.6-4.8), and 0.4% (0.3-0.5), respectively. The average CCT by RTVue (529 mum) was comparable to that by ultrasonic pachymetry (539 mum; P = 0.15), Orbscan (536 mum; P = 0.54), and ASOCT (526 mum; P = 0.77). The 95% limits of agreement on Bland and Altman plots ranged from 20 mum (between RTVue and ASOCT) to 33 mum (between RTVue and Orbscan). CONCLUSIONS: CCT measurements by RTVue have an excellent repeatability. Although CCT measurements by RTVue are comparable to that by ultrasonic pachymetry, Orbscan, and ASOCT, the difference between instruments can be significant depending on the clinical situation considered.
机译:目的:确定(1)通过光谱域光学相干断层扫描(RTVue; Optovue,Inc,Fremont,CA)进行中央角膜厚度(CCT)测量的可重复性,以及(2)RTVue与超声测厚法(Orbscan)进行的CCT测量之间的一致性,以及前段光学相干断层扫描(ASOCT)。方法:在一项前瞻性观察研究中,招募了2个正常受试者队列。在第一个队列(51名受试者)中,RTVue在同一次拜访期间获得了5次CCT测量值,以确定可重复性。在第二组(65名受试者)中,CCT测量是通过在同一次访问期间通过RTVue,超声测厚法,Orbscan和ASOCT获得的,以确定这些仪器之间的一致性。通过组内相关系数(ICC),受试者内部标准偏差,重复性系数和受试者内部变异系数评估重复性。协议由ICC以及Bland和Altman地块评估。结果:根据ICC评估,RTVue对CCT测量的可重复性,受试者内部标准偏差,重复性系数和受试者内部变异系数分别为0.99(0.99-0.99),2.2(1.9-2.5),4.2妈妈(3.6- 4.8)和0.4%(0.3-0.5)。 RTVue(529 mum)的平均CCT与超声测厚法(539 mum; P = 0.15),Orbscan(536 mum; P = 0.54)和ASOCT(526 mum; P = 0.77)相当。在Bland和Altman地块上,协议的95%限制范围为20毫米(在RTVue和ASOCT之间)到33毫米(在RTVue和Orbscan之间)。结论:RTVue的CCT测量具有极好的可重复性。尽管通过RTVue进行的CCT测量与通过超声波测厚法,Orbscan和ASOCT进行的CCT测量相当,但根据所考虑的临床情况,仪器之间的差异可能会很大。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号