The purpose of our study was to determine the diagnostic power of three-dimensional reformatted multi-slice computerized tomography (CT) images on misplaced pedicle screws in spinal surgery. Eighty-four consecutive patients with 458 screws in situ were investigated prospectively using both axial CT slices and reformatted images after operation by two blinded investigators. All the screw misplacements were documented and the differences between the two imaging modalities were recorded. Axial CT slices were able to show only 23 of 60 misplaced pedicle screws; multi-slice CT was three times more powerful in the diagnosis of pedicle screw complications in spinal surgery (p<0.05). We concluded that multi-slice CT reconstruction should be the primary diagnostic tool after screw implantation in the human spine.
机译:我们研究的目的是确定在脊柱外科手术中错位的椎弓根螺钉对三维格式化的多层计算机断层扫描(CT)图像的诊断能力。由两名不知情的研究者在手术后同时使用轴向CT切片和重新格式化的图像,对84例原位458螺钉的连续患者进行了前瞻性研究。记录所有螺钉错位情况,并记录两种成像方式之间的差异。轴向CT切片只能显示60个错位的椎弓根螺钉中的23个。多层CT在脊柱外科椎弓根螺钉并发症的诊断中具有三倍的优势(p <0.05)。我们得出的结论是,多层螺旋CT重建应该是人体脊柱螺钉植入后的主要诊断工具。