首页> 外文期刊>Somatosensory & motor research >Reliability of a new technique for intraoral mapping of somatosensory sensitivity
【24h】

Reliability of a new technique for intraoral mapping of somatosensory sensitivity

机译:体感敏感度口腔内测绘新技术的可靠性

获取原文
获取原文并翻译 | 示例
           

摘要

Diagnosis of intraoral pain conditions may be facilitated by assessment of somatosensory sensitivity not only at a single test site but also at multiple test sites, that is, intraoral somatosensory mapping. No standardized mapping techniques are currently available. The aim of this study was to evaluate: (1) spatial variations in somatosensory sensitivity; (2) the reliability of a new technique for mapping of intraoral somatosensory sensitivity. Fifteen healthy volunteers participated in two experimental sessions. In each session, three mechanical stimuli (32mN and 512mN von Frey and electronic von Frey (EVF)) were each applied to 15 test sites in a 5×3 matrix located at the gingivomucosal area adjacent to the upper premolar region on both sides. A custom-made silicone-based template secured standardization of the test sites. The subjects rated the perceived intensity on a 0-50-100 numerical rating scale (NRS) for tactile (32mN) and pinprick (512mN) stimuli and determined the pinprick threshold (PiPT) by EVF by pushing a stop button. Analyses of variance for NRS scores and PiPT for all three stimulus modalities showed no significant differences between sessions or sides (p=0.077), whereas there were significant site-to-site differences (p<0.001). Generally, the anterior and apical regions were more sensitive than posterior and cervical regions. Intraclass correlation coefficients for between session reliability ranged between 0.76 and 0.87 for NRS scores and PiPT measures. In conclusion, good test-retest reliability of intraoral somatosensory mapping was found with the help of a new template, which can be used for further studies of intraoral pain mechanisms.
机译:通过不仅在单个测试部位而且在多个测试部位的体感敏感性的评估可以促进口腔内疼痛状况的诊断,即口腔内体感测绘。当前没有标准化的映射技术。这项研究的目的是评估:(1)体感敏感性的空间变化; (2)口内体感敏感性测绘新技术的可靠性。 15名健康志愿者参加了两次实验。在每个阶段中,将三个机械刺激(32mN和512mN von Frey和电子von Frey(EVF))分别施加到位于两侧前上磨牙区域附近的牙龈粘膜区域的5×3矩阵中的15个测试部位。定制的基于有机硅的模板确保了测试站点的标准化。受试者对触觉(32mN)和针刺(512mN)刺激以0-50-100数字评分等级(NRS)评估感知强度,并通过按下停止按钮通过EVF确定针刺阈值(PiPT)。所有三种刺激方式的NRS得分和PiPT的方差分析显示,各阶段或两侧之间无显着差异(p = 0.077),而站点之间存在显着差异(p <0.001)。通常,前部和顶端区域比后部和宫颈区域更敏感。对于NRS得分和PiPT量度,会话可靠性之间的类内相关系数在0.76和0.87之间。总之,借助于新模板,发现口内体感测绘具有良好的重测信度,该模板可用于进一步研究口内疼痛机制。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号