Acquired Pseudo-Brown's syndrome immediately following Ahmed valve glaucoma implant.

机译:艾哈迈德瓣膜青光眼植入后立即获得伪布朗综合征。

获取原文
获取原文并翻译 | 示例
           

摘要

A 76-year-old woman noted vertical and horizontal diplopia one day following placement of an Ahmed valve in the superonasal quadrant of her left eye. She was unable to elevate her left eye, especially in adduction. She refused implant removal and strabismus surgery alone failed to satisfactorily resolve her problem. On forced duction testing, the implant became wedged between the globe and orbit superonasally. Subsequent repositioning of the valve resulted in resolution of her motility problem. Implant-orbital disproportion can produce a pseudo-Brown's syndrome. Surgeons are encouraged to perform forced duction testing at the time of glaucoma implant placement to detect and prevent this complication.
机译:一名76岁妇女在将Ahmed瓣膜置于左眼上鼻象限后一天出现垂直和水平复视。她无法抬高左眼,特别是在内收方面。她拒绝移除植入物,仅斜视手术无法令人满意地解决她的问题。在强制引气测试中,植入物被楔入球体和超耳道之间。随后瓣膜的重新定位解决了她的运动问题。植入物-轨道不成比例可产生假布朗氏综合征。鼓励外科医生在放置青光眼植入物时进行强迫诱导测试,以检测和预防这种并发症。