首页> 外文期刊>Microchemical Journal: Devoted to the Application of Microtechniques in all Branches of Science >Closed-vessel microwave acid digestion of commercial maple syrup for the determination of lead and seven other trace elements by inductively coupled plasma-mass spectrometry
【24h】

Closed-vessel microwave acid digestion of commercial maple syrup for the determination of lead and seven other trace elements by inductively coupled plasma-mass spectrometry

机译:商用枫糖浆封闭容器微波酸消解-电感耦合等离子体质谱法测定铅和其他七种微量元素

获取原文
获取原文并翻译 | 示例
           

摘要

A method was developed and applied for the determination of lead and other trace elements (As, Cd, Co, Cu, Mn, V and Zn) in 8 commercial maple syrups. Samples were digested using closed-vessel microwave heating. Two different types of microwave vessels, low-pressure and moderately high-pressure vessels, were evaluated. Average temperatures and maximum pressures attained during the maple syrup sample digestion were 140 degrees C and 190 psi (1310 kPa) for low-pressure vessels and 200 degrees C and 500 psi (3450 kPa) for moderately high-pressure vessels. All digested samples were clear and colorless and their residual carbon content was less than 1%, indicating successful decomposition of the organic matrix. The residual acid concentrations in the final analytical solutions were 2.2 +/- 0.3% and 2.5 +/- 0.2% (w/w) for low and moderately high-pressure vessels, respectively; this is suitable for inductively coupled plasma-mass spectrometery (ICP-MS) analysis. The digested syrup samples were analyzed using ICP-MS. Spike recovery for lead, after digestion in the low-pressure and moderately high-pressure digestion vessels, were 100 +/- 2% (n = 5, 95% CI) and 98 +/- 1% (n = 5, 95% CI), respectively. Satisfactory recoveries were also obtained for seven selected elements. Lead-spiked maple syrup check standards were digested, and lead concentrations were in the range of certified values. Lead levels ranged from 18 to 367 ng/g. Concentrations of seven other trace elements (As, Cd, Co, Cu, Mn, V and Zn) in maple syrup were also determined. (C) 2000 Elsevier Science B.V. All rights reserved. [References: 27]
机译:开发了一种方法,用于测定8种市售枫糖浆中的铅和其他微量元素(As,Cd,Co,Cu,Mn,V和Zn)。使用密闭容器微波加热消化样品。评估了两种不同类型的微波容器,低压容器和中高压容器。枫糖浆样品消解过程中获得的平均温度和最大压力对于低压容器为140摄氏度和190 psi(1310 kPa),对于中高压容器为200摄氏度和500 psi(3450 kPa)。所有消化的样品均是透明无色的,并且其残余碳含量小于1%,表明有机基质已成功分解。最终分析溶液中的低压和中高压容器中残留酸浓度分别为2.2 +/- 0.3%和2.5 +/- 0.2%(w / w);这适用于电感耦合等离子体质谱仪(ICP-MS)分析。使用ICP-MS分析消化的糖浆样品。在低压和中度高压消解容器中消解后,铅的回收率分别为100 +/- 2%(n = 5,95%CI)和98 +/- 1%(n = 5,95%) CI)。七个选定元素的回收率也令人满意。消化了含铅枫糖浆检查标准液,铅浓度在认证值范围内。铅含量范围为18至367 ng / g。还测定了枫糖浆中其他七个痕量元素(As,Cd,Co,Cu,Mn,V和Zn)的浓度。 (C)2000 Elsevier Science B.V.保留所有权利。 [参考:27]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号