首页> 外文期刊>Flow Measurement and Instrumentation >Effects of water in oil and oil in water on single-phase flowmeters
【24h】

Effects of water in oil and oil in water on single-phase flowmeters

机译:油中水和水中油对单相流量计的影响

获取原文
获取原文并翻译 | 示例
           

摘要

The effect of two-phase flow on the performance of a range of single-phase flowmeters has been investigated experimentally using the National Standard Multiphase Flow facilities at NEL. The flowmeters tested were 2-inch and 4-inch positivedisplacement meters, venturi meters, helicoidal and flat-bladed turbine meters, 2-inch U-tube, 3-inch and 1.5-inch straight tube Coriolis meters and a 4-inch vortex shedding meter. The flowmeters were tested in oil flow with water and water flow with oil. The second component fractions were varied from 3% up to 15% by volume. The aim of the project was to quantify the effect of second-phase fluid components on the basic uncertainty of a range of single-phase. These tests have provided evidence of thesuitability of particular flowmeters for two-component flow applications. Comparisons have been made between generic type and size of flow meter. The oil-in-water and water-in-oil tests indicated that the uncertainty in the outputs of the flowmeterstested were generally within± 1% relative to the reference flow-rates, although some errors as high as 5-10% were also observed. Most of the measurements from the turbine flowmeters and the positive displacement flowmeters were within± 0.4% of thereference flow-rates.
机译:已使用NEL的国家标准多相流设施对两相流对一系列单相流量计性能的影响进行了实验研究。测试的流量计为2英寸和4英寸正位移流量计,文氏管流量计,螺旋和平叶片涡轮流量计,2英寸U型管,3英寸和1.5英寸直管科里奥利流量计以及4英寸涡旋脱落仪表。对流量计进行了水油流动和水油流动测试。第二组分的分数在3体积%至15体积%之间变化。该项目的目的是量化第二相流体成分对一系列单相流体基本不确定性的影响。这些测试提供了特定流量计适用于两组分流量应用的证据。在通用类型和流量计尺寸之间进行了比较。水包油和油包水测试表明,相对于参考流量,被测流量计的输出不确定度通常在±1%以内,尽管也观察到一些误差高达5-10% 。涡轮流量计和正排量流量计的大多数测量值均在参考流量的±0.4%之内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号