We report the final results of the trial comparing the Amplatz thrombectomy device (ATD) with surgical thromboembolectomy (ST) to declot thrombosed dialysis access grafts (DAG). The study population consisted of 174 DAG, 109 of which were randomized to mechanical thrombectomy using the ATD and 65 of which were randomized to conventional surgical thromboembolectomy. Forty grafts were re-enrolled in the trial when they failed beyond the 90 days follow-up after the initial treatment. Thirty-one were re-enrolled for mechanical thrombectomy and nine were re-enrolled for surgical thrombectomy, resulting in a total of 140 ATD procedures and 74 surgical thromboembolectomy. Immediate thrombectomy success was defined as greater than 90% thrombus removal followed by the ability to dialyze after treatment, and analysis of long term success based on graft patency at 30 and 90 days, with successful dialysis. Immediate thrombectomy success with the ATD procedure was achieved in 79.2% and with ST in 73.4%. Patency of the graft, with successful dialysis, at 30 days with the ATD procedure was 79.2% and with ST was 73.4%. Patency of the graft, with successful dialysis, at 90 days with the ATD procedure was 75.2% and with ST was 67.8%. The data collected in this study provided a prospective comparison of mechanical thrombectomy with the ATD and ST performance in thrombosed DAG. The results of the performance of both methods were comparable. No statistically significant differences were seen.
机译:我们报告了将Amplatz血栓切除术设备(ATD)与外科血栓栓塞术(ST)进行血栓性血液透析透析移植物(DAG)进行比较的试验的最终结果。研究人群包括174个DAG,其中109个被随机分配到使用ATD进行机械血栓切除术,其中65个被随机分配到常规外科血栓栓塞术。当四十个移植物在初始治疗后的90天随访中失败后,重新入组该试验。机械性血栓切除术重新入组的为31例,外科血栓切除术重新入组的为9例,总共进行了140次ATD手术和74例外科血栓栓塞切除术。立即血栓切除术的成功定义为血栓清除率大于90%,然后经过治疗后具有透析的能力,并基于成功透析30天和90天的移植物通畅性来分析长期成功。使用ATD程序立即完成血栓切除术的成功率为79.2%,使用ST的成功率为73.4%。在30天的ATD手术中,透析成功的移植物的通畅率为79.2%,ST的通畅率为73.4%。在90天的ATD手术中,成功进行透析的移植物的通畅率为75.2%,ST为67.8%。这项研究收集的数据提供了机械血栓切除术与血栓性DAG的ATD和ST表现的前瞻性比较。两种方法的性能结果均具有可比性。没有发现统计学上的显着差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号