首页> 外文期刊>International Orthopaedics >Effect of design on the initial stability of press-fit cups in the presence of acetabular rim defects: experimental evaluation of the effect of adding circumferential fins
【24h】

Effect of design on the initial stability of press-fit cups in the presence of acetabular rim defects: experimental evaluation of the effect of adding circumferential fins

机译:在髋臼缘缺损的情况下设计对压入杯初始稳定性的影响:添加圆周鳍的实验评估

获取原文
获取原文并翻译 | 示例
       

摘要

Purpose This experimental study was undertaken to examine the fixation characteristics of a six-finned acetabular cup in both primary and revision arthroplasty in comparison with two other commonly used cup designs without fins. Methods All three cup designs (Ananova~R [Intraplant], Plasmacup~R NSC [Aesculap]; Exceed ABT? [Biomet]) were implanted into validated models of normal and revision ace-tabula. The defect models were designed to simulate a dorso-cranial rim defect of 90(deg) width and 10 mm in depth (moderate rim defect) and a dorso-cranial rim defect of 130(deg) width and 15 mm in depth (severe rim defect). The fixation strength of the three cup designs was tested by cyclically edge-loading the implanted cups using a mechanical testing machine. Results The six-finned Ananova implant exhibited greater resistance to foam-cup interface motion than both the Plasmacup and Exceed ABT implants. The largest average differences were observed in the resistance to ultimate spin-out, with Ananova outperforming Exceed ABT and Plasmacup by 26 % and 17 % in the moderate and by 36 % and 38 % in the severe defect models, respectively. Conclusions The six-finned Ananova cup was significantly more resistant to edge loading both in the normal acetabulum and in acetabula with moderate to severe dorso-cranial rim defects than cup designs without fins, indicating that it may cover a wider range of clinical indications than conventional press-fit cups and provide clinicians with the confidence that, in primary and simple revision arthroplasty, adequate fixation strength can be obtained.
机译:目的进行本实验研究,以与其他两种不带鳍的常用杯形设计相比,检查六鳍式髋臼杯在原发性和翻修性置换中的固定特性。方法将所有三个杯状设计(Ananova〜R [Intraplant],Plasmacup〜R NSC [Aesculap]; Exceed ABT?[Biomet])植入正常和修订的ace-tabula模型中。设计该缺陷模型​​以模拟90°宽度和深度10毫米的背颅骨边缘缺损(中等边缘缺损)和130°度和深度15毫米的背颅骨边缘缺损(严重边缘)缺陷)。通过使用机械测试机对植入的杯子进行循环边缘载荷来测试这三种杯子设计的固定强度。结果六鳍Ananova植入物比Plasmacup和Exceed ABT植入物对泡沫杯界面运动的抵抗力更大。在最终抗剥离性方面观察到最大的平均差异,在中等缺陷模型中,Ananova的性能分别超过Exceed ABT和Plasmacup,分别为26%和17%,分别为36%和38%。结论相比于无鳍杯设计,六鳍Ananova杯对正常髋臼和髋臼具有中等至严重背颅缘缺损的髋臼边缘载荷的抵抗力要强得多,这表明其覆盖的临床适应症可能比传统的更广泛压配合杯,使临床医生确信,在初次和简单翻修置换术中,可以获得足够的固定强度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号