Calorimetric measurements of the dynamics of a finned adsorbent: early assessment of the activated carbon cloth-ethanol pair with prismatic aluminium fins

机译:翅片吸附剂动力学的量热测量:活性炭布-乙醇对与棱形铝翅片的早期评估

获取原文
获取原文并翻译 | 示例
           

摘要

The heat of adsorption of the pair ethanol-activated carbon cloth (ACC) has been measured in a specialised calorimeter, following a step change in vapour pressure (the "large pressure jump", LPJ) or a step change in temperature of the fin base (the "large temperature jump", LTJ). This is the first time that LTJ has been attempted with this particular technique. The ACC was incorporated into a set of fins, representing small sections of finned tube adsorbent bed (similar to 50 gram mass) and with a fin-to-fin gap of 6 mm. The heat rejection fitted an exponential decay, and for purposes of data fitting was adequately described by exponential decay, notwithstanding multiple physical effects within the ACC pack. Characteristic times, tau, were established for LPJ and LTJ. The characteristic times were adjusted to allow for sensible heat of the sample, making them indicative of change in refrigerant uptake and cooling power. For instance, for the LTJ 338 K -> 303 K, the characteristic time was 146 s without adjustment, but 183 s with adjustment. For the fins tested under LTJ, an "average" specific cooling power, defined with cycle time = 1.6 was in the range of 0.36 to 0.52 kW kg(-1), somewhat smaller than seen elsewhere and requiring future optimisation of the finned sample. (C) 2015 Elsevier Ltd. All rights reserved.
机译:在蒸气压阶跃变化(“大压力跃升”,LPJ)或翅片底座温度阶跃变化之后,已在专用量热计中测量了乙醇活化碳布对的吸附热。 (“大温度跳变”,LTJ)。这是首次使用这种特定技术尝试LTJ。 ACC被合并到一组翅片中,代表翅片管吸附床的小部分(约50克质量),翅片与翅片之间的间隙为6 mm。散热符合指数衰减,尽管为了进行数据拟合,但指数衰减已被适当地描述,尽管在ACC组件中存在多种物理影响。建立了LPJ和LTJ的特征时间tau。调整特征时间以允许样品产生显热,使其指示制冷剂吸收量和冷却能力的变化。例如,对于LTJ 338 K-> 303 K,特征时间在不进行调整的情况下为146 s,而在进行调整的情况下为183 s。对于在LTJ下测试的散热片,定义为“平均”的特定冷却功率(循环时间= 1.6)在0.36至0.52 kW kg(-1)的范围内,比其他地方看到的要小一些,并且需要对散热片样品进行将来的优化。 (C)2015 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号