首页> 外文期刊>Analytical methods >A quantitative assessment of the chemical variation in food grade polyethylene cling film, a common wrapping material for illicit drugs, using attenuated total reflection-Fourier transform infrared spectroscopy
【24h】

A quantitative assessment of the chemical variation in food grade polyethylene cling film, a common wrapping material for illicit drugs, using attenuated total reflection-Fourier transform infrared spectroscopy

机译:使用衰减全反射-傅里叶变换红外光谱法对食品级聚乙烯保鲜膜(一种用于非法药物的常用包装材料)中的化学变化进行定量评估

获取原文
获取原文并翻译 | 示例
           

摘要

Cling film is commonly encountered in forensic investigations as a wrapping for drugs of abuse. The evidential value of a match between a known and a questioned piece of cling film is directly related to the level of the chemical variation both within and between samples. However, little is known about the chemical variation in cling film. To address this, attenuated total reflection-Fourier transform infrared spectroscopy (ATR-FTIR) was used to quantitatively assess the chemical variation in food grade low-density polyethylene (LDPE) cling film. Following acquisition of full scan IR spectra between 4000 and 650 cm~(-1), a spectral region of potential discrimination between 1560 and 1200 cm~(-1) was identified. The Complex series of weak, overlapping absorption bands in this region were deconvoluted and peaks fitted. Bivariate plots comparing each pair of normalised peak areas showed significant overlap of the data points for the different samples, indicating no between-sample chemical variation. Further, the same plots demonstrated that the extent of within-sample chemical variation was at least as great as that between samples. Thus, in the sample set evaluated in this study, it was not possible to discriminate between food grade LDPE cling films using ATR-FTIR spectroscopy due to a lack of quantifiable chemical variation. The study therefore highlights the possibility of false positive matches in the analysis of LDPE cling films and provides a methodology to evaluate the extent of chemical variation in a relevant reference population prior to undertaking casework.
机译:在法医调查中通常会使用保鲜膜作为滥用​​药物的包装。一块已知的和有问题的保鲜膜之间匹配的证据价值直接与样品内部以及样品之间的化学变化水平有关。但是,对于保鲜膜的化学变化知之甚少。为了解决这个问题,使用了衰减全反射傅里叶变换红外光谱(ATR-FTIR)来定量评估食品级低密度聚乙烯(LDPE)保鲜膜中的化学变化。在获取4000至650 cm〜(-1)之间的全扫描IR光谱后,确定了1560至1200 cm〜(-1)之间的电位辨别光谱区域。对该区域中复杂的,弱的,重叠的吸收带系列进行反卷积并拟合峰。比较每对归一化峰面积的双变量图显示了不同样品的数据点有明显的重叠,表明样品之间没有化学变化。此外,相同的图表明,样品内化学变化的程度至少与样品之间的变化一样大。因此,在这项研究中评估的样品集中,由于缺乏可量化的化学变化,因此无法使用ATR-FTIR光谱法区分食品级LDPE保鲜膜。因此,该研究强调了在LDPE保鲜膜的分析中出现假阳性匹配的可能性,并提供了在进行案例研究之前评估相关参考人群中化学变化程度的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号