...
首页> 外文期刊>Fetal diagnosis and therapy >Fetal Tricuspid Regurgitation in the First Trimester as a Screening Marker for Congenital Heart Defects: Systematic Review and Meta-Analysis
【24h】

Fetal Tricuspid Regurgitation in the First Trimester as a Screening Marker for Congenital Heart Defects: Systematic Review and Meta-Analysis

机译:胎儿三丘脑反流妊娠期作为先天性心脏缺陷的筛选标志:系统评价和荟萃分析

获取原文
获取原文并翻译 | 示例
           

摘要

Background: Assessment of tricuspid flow has been reported to improve the performance of screening for aneuploidies and congenital heart defects (CHD). However, the performance of tricuspid regurgitation (TR) as a screening marker for CHD in euploid fetuses is yet to be established. The main aim of this meta-analysis was to establish the predictive accuracy of TR for CHD. Methods: MEDLINE, Embase, and the Cochrane Library were searched electronically utilizing combinations of the relevant medical subject heading for "fetus," " tricuspid regurgitation," and " first trimester." The outcomes explored were prevalence of TR in an euploid population, strength of association between TR and CHD, and predictive accuracy of TR for CHD in euploid fetuses. Summary estimates of sensitivity, specificity, positive and negative likelihood ratios, and diagnostic odds ratio for the overall predictive accuracy of TR for the detection of CHD were computed using the hierarchical summary receiver-operating characteristics model. Results: A total of 452 articles were identified; 60 were assessed with respect to their eligibility for inclusion and a total of 4 studies were included in the study. TR was associated with an increased risk of CHD (RR: 9.6, 95% CI 2.8-33.5; I-2 : 92.7%). The strength of association between TR and CHD persisted when considering fetuses at risk for CHD, such as those with increased nuchal translucency (RR: 7.2, 95% CI 5.2-9.8; I-2 : 0%), while TR did not show any association with CHD when detected in a population at low risk for cardiac defects (RR: 9.3, 95% CI 0.8-111.8; I-2 : 93%). The overall diagnostic performance of TR in detecting CHD was poor in detecting CHD (sROC: 0.684, SE: 0.61) with a sensitivity of 35.2% (95% CI 26.9-44.1) and a specificity of 98.6% (95% CI 98.5-98.7). Detection of TR at the 11-14 weeks' scan showed a positive likelihood ratio of 7.2 (95% CI 5.3-9.8) in detecting CHD when applied to a population at risk for CHD such as fetuses with an increased nuchal translucency. Conclusion: The detection of TR in the first trimester increases the risk of CHD. However, isolated TR in the first trimester does not seem to be a strong predictor for CHD. (C) 2017 S. Karger AG, Basel
机译:None

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号