首页> 外文期刊>Analytical and bioanalytical chemistry >Comparison of different mass spectrometric detection techniques in the gas chromatographic analysis of pyrethroid insecticide residues in soil after microwave-assisted extraction
【24h】

Comparison of different mass spectrometric detection techniques in the gas chromatographic analysis of pyrethroid insecticide residues in soil after microwave-assisted extraction

机译:微波辅助萃取土壤中拟除虫菊酯类农药残留的气相色谱分析中不同质谱检测技术的比较

获取原文
获取原文并翻译 | 示例
           

摘要

A comparative study was carried out for the simultaneous determination of 11 pyrethroid insecticides in soil by gas chromatography (GC) - ion trap (IT)- mass spectrometry (MS), by means of two different ionization modes; electron impact and negative chemical ionization and three data acquisition procedures; full scan, selected ion monitoring and MS/MS. Pyrethroids investigated were tetramethrin, bifenthrin, phenothrin, lambda-cyhalothrin, permethrin, cyfluthrin, cypermethrin, flucythrinate, esfenvalerate, fluvalinate and deltamethrin. Soil samples were treated with toluene/water by microwave-assisted extraction for 9 min at 700 W and a cleaning up with florisil was performed. Clean soil samples were spiked with pyrethroids at a spiking level of 10, 25 and 50 ng/g. The method employed provides a concentration factor of 10. The ionization gas employed in the negative chemical ionization mode was methane. The use of MS/MS acquisition, in electron impact ionization, provided the best results, due to its high selectivity and sensitivity, giving very low limits of detection from 0.08 to 0.54 ng/g. In negative chemical ionization full scan and selected ion monitoring methods detection limits from 0.12 to 1.40 ng/g were found. The proposed methods were applied to several levels from 10 to 50 ng/g of spiked soils, being electron impact MS/MS method which minimizes matrix spectrum interferences and provided recovery average values from 84% to 120% with relative standard deviations which varied from 3.2 to 7.2%.
机译:通过两种不同的电离模式,通过气相色谱(GC)-离子阱(IT)-质谱(MS)同时测定土壤中11种拟除虫菊酯类杀虫剂的比较研究。电子冲击和负化学电离及三种数据采集程序;全扫描,选定的离子监测和MS / MS。所研究的拟除虫菊酯为四氯菊酯,联苯菊酯,吩噻菌灵,λ-氯氟氰菊酯,氯菊酯,环氟氰菊酯,氯氰菊酯,氟氰菊酯,艾芬戊酸酯,氟伐林酸酯和溴氰菊酯。用甲苯/水通过微波辅助萃取在700 W下处理土壤样品9分钟,然后用弗罗里西尔进行清洁。清洁的土壤样品中掺有拟除虫菊酯类农药,掺料浓度为10、25和50 ng / g。所使用的方法提供的浓缩系数为10。在负化学电离模式下使用的电离气体为甲烷。由于其高选择性和灵敏度,在电子碰撞电离中使用MS / MS采集可提供最佳结果,检测限从0.08到0.54 ng / g非常低。在负化学电离全扫描和选定的离子监测方法中,检出限为0.12到1.40 ng / g。拟议的方法适用于10到50 ng / g掺加土壤的数种水平,这是一种电子碰撞MS / MS方法,可将基质光谱干扰降至最低,并提供84%至120%的回收平均值,相对标准偏差为3.2。到7.2%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号