首页> 外文期刊>Drug testing and analysis >Development and validation of a liquid chromatography-tandem mass spectrometry method for simultaneous detection of 10 illicit drugs in oral fluid collected with FLOQSwabs (TM) and application to real samples
【24h】

Development and validation of a liquid chromatography-tandem mass spectrometry method for simultaneous detection of 10 illicit drugs in oral fluid collected with FLOQSwabs (TM) and application to real samples

机译:液相色谱 - 串联质谱法同时检测10例用Floqswabs(TM)中的10个非法药物和实际样品的液体液中的10个非法药物的开发和验证

获取原文
获取原文并翻译 | 示例
           

摘要

According to French law, the roadside testing for drugs of abuse (DOA) should be performed in oral fluid (OF) using an immunological screening kit. If the screening is positive, confirmation has to be done in OF collected by a special swab, called the FLOQSwab (TM) (FS). Unlike other sampling kits, this device was not designed to collect OF since it does not contain an elution buffer. An analytical method was developed for the simultaneous detection of 10 DOA under control in France: tetrahydrocannabinol (THC) at 1 ng/mL, and cocaine, benzoylecgonine (BZE), morphine, 6-monoacetylmorphine (6-MAM), amphetamine, methamphetamine, 3,4-methylenedioxy-N-ethylamphetamine (MDEA), 3,4-methylenedioxyamphetamine (MDA), and 3,4-methylenedioxy-N-methylamphetamine (MDMA) at 10 ng/mL. Samples were eluted using the Quantisal buffer and extracted by liquid-liquid extraction for THC and by solid-phase extraction for the remaining analytes. Analyses were performed by ultra-high performance liquid chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS). The validated method made it possible to detect the concentrations required by law and was successfully applied to samples from drivers who screened positive. The main limitations of this kit are the large variability of the collected OF volume and the poor stability of DOA in OF, requiring the use of a conservation buffer.
机译:据法国法律介绍,滥用药物(DOA)的路边试验应使用免疫筛查试剂盒在口腔液体(OF)中进行。如果筛选是阳性的,则必须在由特殊拭子收集的确认,称为FLOQSWAB(TM)(FS)。与其他采样试剂盒不同,该设备未设计成收集,因为它不包含洗脱缓冲区。开发了一种分析方法,用于在法国控制中同时检测10 DOA:四氢甘油(THC)在1ng / ml,Cocaine,苯甲酰葡萄糖(BZE),吗啡,6-单乙酰常(6-MAM),安非他明,甲基丙酮, 3,4-甲基二氧基-N-乙基丙酮(MDEA),3,4-亚甲二氧基苯丙胺(MDA)和3,4-亚甲基二氧基-N-甲基丙胺(MDMA),在10ng / mL。使用量子缓冲液洗脱样品,并通过液 - 液萃取萃取THC,并通过固相萃取剩余的分析物。通过超高效液相色谱法与串联质谱(UHPLC-MS / MS)偶联进行分析。经过验证的方法使得可以检测法律所需的浓度,并成功地应用于筛选阳性的驱动器的样品。该试剂盒的主要局限性是体积收集的大幅度和DOA的稳定性差,需要使用保护缓冲液。

著录项

  • 来源
    《Drug testing and analysis》 |2019年第6期|共9页
  • 作者单位

    Univ Versailles St Quentin Plateforme MasSpecLab U INSERM 1173 UFR Simone Veil 2 Ave Source;

    Univ Versailles St Quentin Plateforme MasSpecLab U INSERM 1173 UFR Simone Veil 2 Ave Source;

    Hop Raymond Poincare AP HP Lab Pharmacol &

    Toxicol 104 Blvd Raymond Poincare F-92380 Garches;

    Hop Raymond Poincare AP HP Lab Pharmacol &

    Toxicol 104 Blvd Raymond Poincare F-92380 Garches;

    Hop Raymond Poincare AP HP Lab Pharmacol &

    Toxicol 104 Blvd Raymond Poincare F-92380 Garches;

    Univ Versailles St Quentin Plateforme MasSpecLab U INSERM 1173 UFR Simone Veil 2 Ave Source;

    Univ Versailles St Quentin Plateforme MasSpecLab U INSERM 1173 UFR Simone Veil 2 Ave Source;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 药学;
  • 关键词

    oral fluid; drugs of abuse; tandem mass spectrometry; FLOQSwab (TM);

    机译:口腔液体;滥用药物;串联质谱;FLOQSWAB(TM);

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号