...
首页> 外文期刊>AJNR. American journal of neuroradiology >Blood flow changes caused by distal filter protection and catheter aspiration in the internal carotid artery during carotid stenting: evaluation using carotid Doppler sonography.
【24h】

Blood flow changes caused by distal filter protection and catheter aspiration in the internal carotid artery during carotid stenting: evaluation using carotid Doppler sonography.

机译:在颈动脉支架置入过程中,由于远端滤器保护和颈内动脉导管抽吸引起的血流变化:使用颈动脉多普勒超声检查进行评估。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND AND PURPOSE: If blood flow in the ICA is reduced by the use of a distal filter during CAS, flow stagnation proximal to the filter occurs and this increases the probability of floating debris. The floating debris that remains after filter retrieval may cause cerebral embolism. However, if blood flow is increased by aspiration of blood from the ICA through an aspiration catheter, debris could be removed while the filter is still in place. The purpose of this study was to investigate blood flow changes in the ICA induced by filter use and aspiration. MATERIAL AND METHODS: A filter-protection device (AngioGuard XP) was used during CAS in 13 consecutive patients with carotid stenosis. Blood flow velocity in the ICA was measured by carotid Doppler sonography during filter deployment, filter retrieval, and catheter aspiration. RESULTS: Blood flow velocity significantly decreased with filter placement and significantly increased with filter retrieval in patients with normal angiographic flow (P < .05). Aspiration of a 20-mL blood sample from the proximal ICA column significantly increased the blood flow velocity (P < .05). CONCLUSIONS: The blood flow changes in the ICA induced by the use of a distal filter may cause cerebral embolism in filter-protected CAS. A routine aspiration method can potentially reduce the amount of migrating debris during CAS, even in cases with angiographic normal flow.
机译:背景与目的:如果在CAS期间通过使用远端过滤器减少了ICA中的血流,则在过滤器附近会出现血流停滞,这会增加漂浮碎片的可能性。取回过滤器后残留的漂浮碎片可能导致脑栓塞。但是,如果通过抽吸导管从ICA抽吸血液来增加血流量,则可以在过滤器仍在原位的同时清除碎屑。这项研究的目的是调查因使用过滤器和抽吸引起的ICA血流变化。材料与方法:CAS期间连续13例颈动脉狭窄患者使用了过滤器保护装置(AngioGuard XP)。 ICA内的血流速度通过滤器展开,滤器取出和导管抽吸期间的颈动脉多普勒超声测量。结果:在正常血管造影流量的患者中,血流速度随滤器放置而显着降低,随滤器恢复而显着增加(P <.05)。从近端ICA柱抽吸20 mL血液样本可显着提高血流速度(P <.05)。结论:使用远端滤器引起的ICA血流变化可能导致滤器保护的CAS发生脑栓塞。即使在血管造影正常血流的情况下,常规抽吸方法也有可能减少CAS期间的迁移碎屑数量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号