...
首页> 外文期刊>Ophthalmic epidemiology >Repeatability and Reproducibility of Slit Lamp, Optical Coherence Tomography, and Scheimpflug Measurements of Corneal Scars
【24h】

Repeatability and Reproducibility of Slit Lamp, Optical Coherence Tomography, and Scheimpflug Measurements of Corneal Scars

机译:切片灯,光学相干性断层扫描和角膜疤痕的重复性和再现性

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Purpose: To determine the repeatability and reproducibility of anterior segment optical coherence tomography (AS-OCT) and Scheimpflug photography for several measurements of corneal scars, including scar size, scar depth, and corneal thickness.Methods: A series of patients treated for fungal keratitis at a tertiary eye care center in South India were recalled two years after successful treatment. Eyes with corneal scars had a slit lamp examination performed by two ophthalmologists masked to the other's examination. For AS-OCT and Scheimpflug photography, each eye had two scans taken by one technician and a third scan taken by a separate technician. Scar measurements were subsequently assessed from AS-OCT images by three graders masked to each other's results. Repeatability and reproducibility were assessed by calculating the intra-class correlation coefficient (ICC) from mixed effects linear regression models.Results: Fifty eyes had all measurements taken. The corneal scar size, measured as the geometric mean of the two longest perpendicular meridians, ranged from 0.8 to 5.4 (mean 2.8 mm, 95%CI 2.6 to 3.1). Scar size measurements taken by two separate individuals were most reproducible when the border of the scar was traced from the OCT (ICC 0.90, 95%CI 0.86 to 0.94), and least repeatable when assessed from slit lamp examination (ICC 0.80, 95%CI 0.70 to 0.90).Conclusions: AS-OCT and Scheimpflug imaging of corneal scars produced measurements with acceptable reproducibility that could be useful as cornea-specific outcomes for clinical trials.
机译:目的:确定前段光学相干断层扫描(AS-OCT)和Scheimpflug摄影的重复性和再现性,用于几次角膜疤痕,包括瘢痕尺寸,瘢痕深度和角膜厚度。方法:一系列患者治疗真菌角膜炎在成功治疗后,在印度南部的三级眼部护理中心被召回。眼球疤痕的眼睛具有由两名眼科医生进行的缝隙灯检查,掩盖了对方的检查。对于AS-OCT和Scheimpflug摄影,每只眼睛都有两个技术人员采取的两次扫描,并由单独的技术人员拍摄的第三次扫描。随后从AS-OCT图像评估瘢痕测量,通过三个分级机屏蔽彼此的结果。通过计算来自混合效应线性回归模型的类内相关系数(ICC)来评估可重复性和再现性。结果:五十只眼睛都有所有测量。角膜瘢痕尺寸为两个最长垂直子午线的几何平均值,范围为0.8至5.4(平均2.8 mm,95%CI 2.6至3.1)。当瘢痕的边界从OCT(ICC 0.90,95%CI 0.86至0.94)追踪时,两个单独的个体疤痕尺寸测量最可重复,并且当从狭缝灯检查评估时至少可重复(ICC 0.80,95%CI) 0.70至0.90).Conclusions:角膜疤痕的AS-OCT和Scheimpflug成像产生了可接受的再现性,可用作临床试验的角膜特异性结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号