...
首页> 外文期刊>Respiration: International Review of Thoracic Diseases >Lobar Quantification by Ventilation/Perfusion SPECT/CT in Patients with Severe Emphysema Undergoing Lung Volume Reduction with Endobronchial Valves
【24h】

Lobar Quantification by Ventilation/Perfusion SPECT/CT in Patients with Severe Emphysema Undergoing Lung Volume Reduction with Endobronchial Valves

机译:通过肺气肿的肺部体积减少肺部瓣膜肺部肺部患者的通风/灌注SPECT / CT量罗巴尔量化

获取原文
获取原文并翻译 | 示例
           

摘要

Background: Endoscopic lung volume reduction (ELVR) therapy using one-way valves is used to treat chronic obstructive pulmonary disease patients with severe heterogeneous emphysema. A successful treatment results in atelectasis of the treated pulmonary lobe with subsequent reduction of ventilation (V) and perfusion (Q). Objective: We evaluated the effects of ELVR on the targeted lobe using a new 3-dimensional ventilation and perfusion (V/Q) single-photon emission computed tomography (SPECT)/computed tomography (CT) analysis, which allows for simultaneous semi-automatic lobar pulmonary quantification of volume, ventilation and perfusion, on the first consecutive patients treated with ELVR at Rigshospitalet, Denmark. V/Q planar scintigraphy and V/Q SPECT/CT and lung function measurements were performed before and 6 months after intervention. Results: We included 24 subjects (60 years, range 46-74 years; 37.5% men) with a baseline FEV1 of 25% predicted and RV of 257% predicted. V/Q SPECT/CT-assessed volume of the targeted lobe decreased by a mean of -395 mL and a relative mean of -26.8%, whilst ventilation and perfusion decreased by a relative mean of -37.1 and -25.7%. There was a significant increase in the same parameters of the non-targeted lobe(s) on the ipsilateral side. None of these changes were found in the analysis of planar V/Q imaging. The total lung volume decreased on average by -420 mL. Six months after ELVR, FEV1 had increased by 22%. Significant correlations were found between changes in FEV1 and changes in the volume of the treated lobe (SPECT/CT). Conclusion: Semi-automatic SPECT/CT analysis can quantify volume, ventilation and perfusion changes in pulmonary lobes and may be used in the assessment of patient eligibility for ELVR, identifying target lobes, and evaluation of the regional effects of treatment.
机译:背景:使用单向阀的内镜肺体积减少(ELVR)治疗用于治疗具有严重异质肺气肿的慢性阻塞性肺病患者。成功的治疗导致治疗肺叶的天肠,随后减少通气(V)和灌注(Q)。目的:我们使用新的三维通风和灌注(V / Q)单光子发射计算断层扫描(SPECT)/计算机断层扫描(CT)分析来评估ELVR对目标叶片对目标叶片的影响,允许同时半自动鸭绿肺量化的体积,通风和灌注,在丹麦刚毛斯科斯·雷尔斯治疗的第一个连续患者上。 V / Q平面闪烁和V / Q SPECT / CT和肺功能测量在干预后和6个月之前进行。结果:我们包括24项科目(60岁,范围46-74岁; 37.5%的男性),基线FEV1预测,预测257%的RV。 v / q Spect / Ct评估的靶叶的体积均由-395ml的平均值和-26.8%的相对平均值,而通气和灌注的相对平均值降低-37.1和-25.7%。在同侧侧的非靶向凸角的相同参数显着增加。在平面V / Q成像分析中没有发现这些变化。总肺体积平均降低-420mL。 ELVR后六个月,FEV1增加了22%。在FEV1的变化和处理过的叶片(SPECT / CT)的变化之间发现了显着的相关性。结论:半自动SPECT / CT分析可以量化肺裂片中的体积,通风和灌注变化,可用于评估ELVR的患者资格,鉴定靶叶,以及对治疗区域影响的评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号