Introduction: The remOVE System (Ovesco Endoscopy AG, Tuebingen, Germany) is a medical device for the endoscopic removal of OTSC or FTRD clips (Ovesco Endoscopy AG, Tuebingen, Germany). The aim of this paper is to assess the efficacy and safety of this system. Material and methods: A total of 74 patients underwent clip extraction. The standard removal procedure comprises fragmenting the clip by applying an electrical direct current pulse at two opposing sides of the clip. Results: Clip fragmentation was successful in 72 of 74 patients (97.3%). In two cases (2.7%) clip fragmentation was not possible. In nine cases (12.2%) a clip fragment could not be removed and was left in place. Complications occurred in three cases (4.1%): two minor bleedings near the clip removal site (2.7%), and one superficial mucosal tear resulting from clip fragment extraction (1.4%). Discussion: Based on this study, the use of the remOVE System for OTSC or FTRD clip removal can be considered safe and effective.
机译:简介:删除系统(ovesco内窥镜,德国Tuebingen,德国)是用于内窥镜去除Otsc或Ftrd夹(杂志内窥镜,德国的玻璃镜,德国)的医疗装置。 本文的目的是评估该系统的疗效和安全性。 材料和方法:共有74例患者接受夹子提取。 标准移除过程包括通过在夹子的两个相对侧施加电直流电流脉冲来分段。 结果:夹子碎片成功74名患者的72例(97.3%)。 在两种情况下(2.7%)夹子碎片是不可能的。 在九种情况下(12.2%)不能去除夹子片段并留在适当位置。 三种情况下发生并发症(4.1%):夹子去除位点附近的两个轻微出血(2.7%),以及由夹子片段提取产生的一种浅表粘膜撕裂(1.4%)。 讨论:根据这项研究,可以认为使用删除系统或FTRD夹子去除可以安全有效。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号