首页> 外文期刊>Metallurgist >Calculation and Analysis of the Relationship Between the Efficiency and Position of Electric Arcs and Power Consumption in Electric Arc Furnaces (EAF) of Smaller and Larger Capacity. Part I. Calculation and Analysis of the Relationship Between Arc Efficiency and Power Consumption
【24h】

Calculation and Analysis of the Relationship Between the Efficiency and Position of Electric Arcs and Power Consumption in Electric Arc Furnaces (EAF) of Smaller and Larger Capacity. Part I. Calculation and Analysis of the Relationship Between Arc Efficiency and Power Consumption

机译:电弧效率与电弧炉(EAF)效率和位置与较大容量较大且较大容量的功耗的计算与分析。 第一部分。电弧效率与功耗之间关系的计算与分析

获取原文
获取原文并翻译 | 示例
           

摘要

The arc efficiency and specific power consumption were calculated and analyzed for the small (1.5 to 20 tons) and large (100 to 120 tons) capacity electric arc furnaces. In the small-capacity furnaces, the increased specific power consumption for melting the furnace charge (475 to 500 kW center dot h/t) is associated with low arc efficiency (0.55 to 0.57). In the large-capacity furnaces, the arc efficiency is 0.78 to 0.8 and specific power consumption is 360 to 375 kW center dot h/t.
机译:计算和分析电弧效率和特定功耗,为小(1.5到20吨)和大(100至120吨)容量电弧炉。 在小容量炉中,用于熔化炉充电的更高的特定功耗(475至500kW中心点H / T)与低电弧效率(0.55至0.57)相关。 在大容量炉中,电弧效率为0.78至0.8,特定功耗为360至375千瓦中心点H / T.