首页> 外文期刊>Computers in Biology and Medicine >Factors affecting accuracy of implant placement with mucosa-supported stereolithographic surgical guides in edentulous mandibles
【24h】

Factors affecting accuracy of implant placement with mucosa-supported stereolithographic surgical guides in edentulous mandibles

机译:影响植入物沉积术术中胶凝式外观手术指南的植入物沉积准确性的因素

获取原文
获取原文并翻译 | 示例
           

摘要

This study aimed to evaluate the accuracy of implant placement with mucosa-supported surgical guides in edentulous mandibles and to determine the factors affecting accuracy. Implant placement was simulated on the preoperative CT image and mucosa-supported surgical guides were fabricated for six edentulous mandible models and 15 patients with edentulous mandibles, using CAD/CAM technology. Deviations of the actual implant position from the planned position were calculated by comparing the planned image and the postoperative image. Based on the results, it was concluded that mucosa-supported surgical guides have high accuracy and that bone density and mucosal thickness could affect accuracy.
机译:本研究旨在评估植入物放置与粘膜支持的外科指南在芯片下颌骨上的准确性,并确定影响精度的因素。 在术前CT图像上模拟植入物置入术前CT图像,使用CAD / CAM技术为六个伪劣的下颌骨型号和15名伪劣颌骨患者制造了粘膜支持的手术指南。 通过比较计划的图像和术后图像来计算实际植入位置与计划位置的偏差。 基于结果,得出结论,粘膜支持的外科指南具有高精度,骨密度和粘膜厚度可能影响精度。