首页> 外文期刊>The Journal of Chemical Physics >High resolution quantum cascade laser spectroscopy of the simplest Criegee intermediate, CH2OO, between 1273 cm(-1) and 1290 cm(-1)
【24h】

High resolution quantum cascade laser spectroscopy of the simplest Criegee intermediate, CH2OO, between 1273 cm(-1) and 1290 cm(-1)

机译:高分辨率量子级联激光光谱,最简单的Criegee中间体,CH2OO,1273厘米(-1)和1290厘米(-1)

获取原文
获取原文并翻译 | 示例
           

摘要

The region 1273-1290 cm(-1) of the nu(4) fundamental of the simplest Criegee intermediate, CH2OO, has been measured using a quantum cascade laser transient absorption spectrometer, which offers greater sensitivity and spectral resolution (<0.004 cm(-1)) than previous works based on thermal light sources. Gas phase CH2OO was generated from the reaction of CH2I + O-2 at 298 K and 4 Torr. The analysis of the absorption spectrum has provided precise values for the vibrational frequency and the rotational constants, with fitting errors of a few MHz. The determined ratios of the rotational constants, A'/A '' = 0.9986, B'/B '' = 0.9974, and C'/C '' = 1.0010, and the relative intensities of the a-and b-type transitions, 90: 10, are in good agreement with literature values from a theoretical calculation using theMULTIMODE approach, based on a high-level ab initio potential energy surface. The low-K (= K-a) lines can be fitted extremely well, but rotational perturbations by other vibrational modes disrupt the structure for K = 4 and K >= 6. Not only the spectral resolution but also the detection sensitivity of CH2OO IR transitions has been greatly improved in this work, allowing for unambiguous monitoring of CH2OO in kinetic studies at low concentrations. Published by AIP Publishing.
机译:使用量子级联激光瞬态吸收光谱仪测量最简单的Criegee中间体,CH2OO的Nu(4)的um(4)基础的区域1273-1290cm(-1),其提供更大的灵敏度和光谱分辨率(<0.004厘米( - 1))比以前的作品基于热光源。通过在298k和4托的CH 2 I + O-2的反应中产生气相CH2OO。吸收光谱的分析为振动频率和旋转常数提供了精确值,具有拟合误差的几MHz。确定旋转常数的比率,“/ a”= 0.9986,b'/ b'= 0.9974,以及c'/ c'= 1.0010,以及a-and b型转换的相对强度, 90:10,基于高级AB Initio势能表面,与使用Themultimode方法的理论计算的文献值吻合良好。低k(= ka)线可以非常好,但其他振动模式的旋转扰动会破坏k = 4和k> = 6的结构。不仅是光谱分辨率,还具有CH2OO IR转换的检测灵敏度在这项工作中得到了极大的改善,允许在低浓度的动力学研究中明确地监测CH2OO。通过AIP发布发布。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号