...
首页> 外文期刊>Analytical chemistry >Sorbent-Impregnated Polyurethane Foam Disk for Passive Air Sampling of Volatile Fluorinated Chemicals
【24h】

Sorbent-Impregnated Polyurethane Foam Disk for Passive Air Sampling of Volatile Fluorinated Chemicals

机译:吸附剂浸渍的聚氨酯泡沫盘,用于挥发性氟化物的被动空气采样

获取原文
获取原文并翻译 | 示例
           

摘要

A passive air sampler comprising a polyurethane foam (PUF) disk impregnated with XAD-4 powder has been developed. This sorbent-impregnated PUF (SIP) disk builds on previous work using PUF disk passive air samplers that have been effective in spatial air mapping studies of nonpolar hydrophobic chemicals, without the need of electricity or expensive air sampling equipment. In this study, PUF disks and SIP disks are calibrated for sampling volatile polyfluorinated chemicals-specifically, the fluorotelomer alcohols (FTOHs) and perfluoroalkyl sulfonamides (PFASs). Results demonstrate the low sorptive capacity of the PUF disk samplers, particularly for the FTOHs, with PUF disks reaching equilibrium within 1 day, after collecting approx0.4 and 1.2 m~(3) of air for 8:2 FTOH and 10:2 FTOH, respectively. This limits their use for these target compounds when time-weighted, linear-phase sampling is desired. The presence of just 0.4 g of XAD powder in the SIP disks greatly increases the sorptive capacity (by approx2 orders of magnitude for the FTOHs) and provides linear-phase sampling for a period of several weeks. PUF-air partition coefficients, K_(PUF-A), calculated for the FTOHs and PFASs are considerably lower than values predicted using previously established correlations against the octanol-air partition coefficient, K_(OA), demonstrating the unique partitioning behavior of the polyfluorinated chemicals. Using results from these calibration tests, air concentrations of FTOHs were derived from PUF disk samples that were deployed in 52 homes in Ottawa, Canada, during 2002/2003. These represent the first comprehensive measurements of FTOHs in indoor air in North America. Range and (geometric mean) air concentrations (pg m~(-3)) were 261-28 900 (2070) for 8:2 FTOH and 104-9210 (890) for 10:2 FTOH. These air concentrations are orders of magnitude higher than observed for outdoor air, establishing indoor environments as important for human exposure and also as potential sources to the larger environment.
机译:已经开发出一种被动空气采样器,该被动空气采样器包括浸渍有XAD-4粉末的聚氨酯泡沫(PUF)盘。这种浸有吸附剂的PUF(SIP)盘是在以前使用PUF盘无源空气采样器进行工作的基础上完成的,该无源空气采样器在非极性疏水性化学物质的空间空气映射研究中非常有效,不需要电力或昂贵的空气采样设备。在这项研究中,对PUF圆盘和SIP圆盘进行了校准,以取样挥发性多氟化物,特别是氟调聚物醇(FTOH)和全氟烷基磺酰胺(PFAS)。结果表明,PUF圆盘采样器的吸附能力很低,尤其是对于FTOH,在8:2 FTOH和10:2 FTOH收集到约0.4和1.2 m〜(3)的空气后,PUF圆盘在1天之内达到平衡。 , 分别。当需要时间加权线性相采样时,这限制了它们在这些目标化合物中的使用。 SIP圆盘中仅存在0.4 g的XAD粉末,极大地提高了吸附能力(对于FTOH,吸附能力提高了大约2个数量级),并提供了数周的线性相位采样。为FTOH和PFAS计算的PUF空气分配系数K_(PUF-A)大大低于使用先前建立的与辛醇-空气分配系数K_(OA)的相关性所预测的值,这证明了多氟化物的独特分配行为化学药品。使用这些校准测试的结果,从2002/2003年间在加拿大渥太华的52个家庭中部署的PUF圆盘样本中得出了FTOH的空气浓度。这些代表了北美室内空气中FTOH的首次综合测量。 8:2 FTOH的范围和(几何平均)空气浓度(pg m〜(-3))为261-28 900(2070),而10:2 FTOH的浓度为104-9210(890)。这些空气浓度比室外空气所观察到的高几个数量级,从而建立了室内环境,这对于人体暴露至关重要,同时也是更大环境的潜在来源。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号