An apparatus has been developed to measure the thermal conductivity of ceramic coatings.Since the method uses an infrared microscope for temperature measurement,coatings as thin as 20 um can,in principle,be measured using this technique.This steady-state,comparative measurement method uses the known thermal conductivity of the substrate material as the reference material for heat-flow measurement,The experimental method is validated by measuring a plasma-sprayed coating that has been previously measured using an absolute,steady-state measurement method.The new measurement method has a relative standard uncertainty of about 10%.The measurement of the plasmasprayed coating gives 0.58W'm-1.K-1which compares well with the 0.62 W'm-1,K-1 measured using the absolute method.
机译:已经开发出一种用于测量陶瓷涂层热导率的设备。由于该方法使用红外显微镜进行温度测量,因此原则上可以使用该技术测量薄至20 um的涂层。这种稳态的比较测量方法使用已知材料的导热系数作为热流测量的参考材料,通过测量先前使用绝对,稳态测量方法测量的等离子喷涂涂层来验证该实验方法。相对标准不确定度约为10%。等离子喷涂涂层的测量结果为0.58W'm-1.K-1,与绝对法测得的0.62 W'm-1,K-1相当。