A new analyzing method for quantification of abrasion on the Bruxcore device for sleep bruxism diagnosis.

机译:一种用于量化Bruxcore设备上的磨损量的新分析方法,用于诊断睡眠磨牙症。

获取原文
获取原文并翻译 | 示例
           

摘要

AIMS: To evaluate a newly developed semi-automatic computer-based method to analyze the objectivity of the Bruxcore Bruxism-Monitoring Device (BBMD) by assessing the interrater reliability. The capability of the BBMD to differentiate between sleep bruxers (SB) and healthy controls was also verified by estimating the sensitivity, specificity, and predictive values. METHODS: Forty-eight SB and 21 controls took part in this investigation. After a detailed clinical dental examination, each participant received a BBMD to be worn for 5 consecutive nights. The BBMDs were then scanned and rated by 2 independent examiners using the new method, which counted the abraded area in pixels. Interrater reliability was assessed by intraclass correlation coefficient (ICC) analyses. RESULTS: The analyses showed a very high interrater reliability of ICC = 0.99, and comparison of the mean pixel scores revealed values that were approximately 8 times higher for the SB than for the controls. With a selected pixel score cutoffpoint of 2900, a sensitivity of 79.2% and a specificity of 95.2% were found. The clinical diagnosis was correctly predicted in 97.4% of the SB and 66.7% of the controls. CONCLUSION: The results support the assumption that the newly developed analyzing method for the assessment of the BBMD is a clinically suitable, objective, and applicable method that seems to be able to differentiate between SB and a healthy control sample. These data, however, need to be confirmed in further investigations using polysomnographic recordings.
机译:目的:评估一种新开发的基于半自动计算机的方法,通过评估间隔可靠性来分析Bruxcore磨牙症监测设备(BBMD)的客观性。通过估计敏感性,特异性和预测值,还证实了BBMD区分布鲁士(SB)和健康对照的能力。方法:48名SB和21名对照参加了这项研究。在进行了详细的临床牙科检查之后,每个参与者都接受了连续5个晚上佩戴的BBMD。然后,使用新方法对BBMD进行扫描,并由2名独立检查员进行评级,该方法以像素为单位对磨损区域进行计数。通过组内相关系数(ICC)分析评估评估者间的可靠性。结果:分析显示,ICC = 0.99的高度间信度很高,平均像素得分的比较显示,SB的值比对照组高约8倍。在选定的2900像素分数截止点下,发现灵敏度为79.2%,特异性为95.2%。 97.4%的SB和66.7%的对照正确预测了临床诊断。结论:结果支持以下假设:新开发的评估BBMD的分析方法是一种临床上合适,客观且可应用的方法,似乎能够区分SB和健康对照样品。但是,这些数据需要在使用多导睡眠图记录的进一步调查中得到确认。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号