Excipient compatibility of a new chemical entity was assessed using an isothermal microcalorimeter. Mixtures of an active pharmaceutical ingredient with a primary amine group and excipients were prepared in a 1:1 ratio and compatibility monitored by exposing to 50, 60 and 70degreesC in presence of 200 muL of water. The new chemical entity, a primary amine, reacted with reducing sugars such as lactose and resulted in a brown discoloration. This reaction is the Maillard type condensation reaction between amines and reducing sugars. The rate of reaction was dependent on the temperature with rapid degradation at higher temperatures. No other incompatibility was apparent between the primary amine and other excipients.
机译:使用等温微量热仪评估了新化学实体的赋形剂相容性。将具有伯胺基的活性药物成分与赋形剂的混合物以1:1的比例进行制备,并通过在200μL水的存在下暴露于50、60和70℃来监测相容性。新的化学实体伯胺与还原糖(例如乳糖)反应,导致褐色变色。该反应是胺和还原糖之间的美拉德型缩合反应。反应速率取决于温度,并在较高温度下迅速降解。伯胺和其他赋形剂之间没有其他不相容性。