Efficiency of radiation protection equipment in interventional radiology: a systematic Monte Carlo study of eye lens and whole body doses

机译:放射防护设备在介入放射学中的效率:对眼镜片和全身剂量的系统性蒙特卡洛研究

获取原文
获取原文并翻译 | 示例
           

摘要

Monte Carlo calculations were used to investigate the efficiency of radiation protection equipment in reducing eye and whole body doses during fluoroscopically guided interventional procedures. Eye lens doses were determined considering different models of eyewear with various shapes, sizes and lead thickness. The origin of scattered radiation reaching the eyes was also assessed to explain the variation in the protection efficiency of the different eyewear models with exposure conditions. The work also investigates the variation of eye and whole body doses with ceiling-suspended shields of various shapes and positioning. For all simulations, a broad spectrum of configurations typical for most interventional procedures was considered. Calculations showed that ‘wrap around’ glasses are the most efficient eyewear models reducing, on average, the dose by 74% and 21% for the left and right eyes respectively. The air gap between the glasses and the eyes was found to be the primary source of scattered radiation reaching the eyes. The ceilingsuspended screens were more efficient when positioned close to the patient’s skin and to the x-ray field. With the use of such shields, the H_p(10) values recorded at the collar, chest and waist level and the H_p(3) values for both eyes were reduced on average by 47%, 37%, 20% and 56% respectively. Finally, simulations proved that beam quality and lead thickness have little influence on eye dose while beam projection, the position and head orientation of the operator as well as the distance between the image detector and the patient are key parameters affecting eye and whole body doses.
机译:蒙特卡洛计算用于研究在荧光镜引导的介入手术过程中辐射防护设备在减少眼睛和全身剂量方面的效率。确定眼镜镜片剂量时要考虑具有不同形状,大小和铅厚的眼镜的不同型号。还评估了到达眼睛的散射辐射的起源,以解释不同眼镜型号的防护效率随暴露条件的变化。这项工作还研究了各种形状和位置的天花板悬挂式防护罩对眼睛和全身剂量的影响。对于所有模拟,都考虑了大多数介入程序典型的广泛配置。计算表明,“环绕式”眼镜是最有效的眼镜型号,平均将左眼和右眼的剂量分别减少了74%和21%。发现眼镜与眼睛之间的气隙是到达眼睛的散射辐射的主要来源。将天花板悬挂的屏幕放置在靠近患者皮肤和X射线场较近的地方,效率更高。使用这种防护罩,在两只项圈的项圈,胸部和腰部处记录的H_p(10)值和两只眼睛的H_p(3)值分别平均降低了47%,37%,20%和56%。最后,仿真证明光束质量和导线厚度对眼睛剂量几乎没有影响,而光束投影,操作员的位置和头部方向以及图像检测器与患者之间的距离是影响眼睛和全身剂量的关键参数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号