Based on the limited ability of the human being to voluntarily control submaximal eccentric exertions, previous studies have indicated that isokinetic testing with a combined concentric-eccentric exercise protocol could effectively identify submaximal (feigned) effort in various muscle groups by showing an abnormally high eccentric to concentric ratio (ECR). The objective of this study was to determine the validity and accuracy of an ECR-based isokinetic test in identifying feigned ankle weakness. Thirty-eight normal subjects performed maximal and feigned efforts in an isokinetic concentric and eccentric ankle plantar- and dorsiflexion protocol with two different velocities, 30 and 120 degrees s(-1). The isokinetic parameters ECR and the derivatives DEC (difference between ECR at high speed of motion and ECR at low speed of motion) and SEC (sum of ECR at high speed of motion plus the ratio between eccentric peak torque at high speed and concentric peak torque at low speed) were calculated. The ECR, DEC and SEC scores were significantly greater in feigned conditions for ankle plantarflexion, but not for dorsiflexion. Using optimal cutoff scores based on 99% tolerance intervals, it was disclosed that the most efficient parameter was the SEC, identifying 92% of the feigned efforts with 99% confidence, indicating that the ankle plantarflexors are less controllable in fast eccentric conditions than that in concentric conditions. The ECR-based parameters are valid for effectively identifying feigned plantarflexion effort with high accuracy, but do not allow the detection of feigned dorsiflexion weakness.
机译:基于人类自愿控制次最大偏心运动的能力有限,先前的研究表明,结合同心-偏心运动方案进行的等速测试可以通过显示异常高的偏心运动来有效地识别各个肌肉组次最大(假装)的力量。同心比(ECR)。这项研究的目的是确定基于ECR的等速测试在识别假性踝关节无力中的有效性和准确性。 38名正常受试者在等速同心和偏心踝an屈和背屈方案中以两种不同的速度(30和120度s(-1))进行了最大程度的动作。等速运动参数ECR和导数DEC(高速运动时的ECR与低速运动时的ECR之差)和SEC(高速运动时ECR的总和加上高速时的偏心峰值转矩与同心峰值转矩之比)在低速下)。在正常情况下,踝足屈曲的ECR,DEC和SEC评分显着更高,而背屈屈曲的ECR,DEC和SEC得分却更高。使用基于99%耐受间隔的最佳截断分数,可以发现,最有效的参数是SEC,可以以99%的置信度识别出92%的假装动作,这表明在快速偏心条件下,踝plant屈的可控性较同心条件。基于ECR的参数可有效准确地识别假性足屈力,但不允许检测假性背屈肌无力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号