...
首页> 外文期刊>Journal of exposure analysis and environmental epidemiology >Dioxin-Like TEQ of women from the Seveso, Italy area by ID-HRGC/HRMS and CALUX.
【24h】

Dioxin-Like TEQ of women from the Seveso, Italy area by ID-HRGC/HRMS and CALUX.

机译:ID-HRGC / HRMS和CALUX对来自意大利塞维索地区妇女的二恶英样TEQ进行了研究。

获取原文
获取原文并翻译 | 示例
           

摘要

Polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and polychlorinated biphenyls (PCBs) are widespread environmental contaminants that exist as complex mixtures and are frequently detected at part-per-trillion (ppt) levels in humans. Using isotope dilution high-resolution gas chromatography/ high-resolution mass spectrometry (HRGC/HRMS), we measure the PCDDs, PCDFs, and PCBs in serum of a population of 78 women residing in an area near Seveso, Italy where a TCDD explosion occurred in 1976 and where furniture is manufactured. The average total dioxin-like toxic equivalents (TEQ) of these women was 25.3 ppt, lipid-adjusted, comparable to other parts of Europe. TCDD levels, however, were higher among the few women who resided in the exposed area in 1976. We examined the possibility of using the CALUX (chemical-activated luciferase gene expression) bioassay to estimate total TEQ in a small volume of plasma from this population. A total of 32 archived plasma specimens were selected for CALUX bioassay, based on the distribution of Total TEQ by HRGC/HRMS. The CALUX bioassay was performed blind to HRGC/HRMS results with 2 ml plasma per replicate analysis. Of 32 samples, 10 were below detection limits in the CALUX bioassay. For the 32 samples, the CALUX-TEQ averaged 25.4 ppt, lipid-adjusted (range: 0-127.6) and was not significantly different from the HRGC/HRMS Total TEQ average of 31.2 ppt, lipid-adjusted (range: 12.7-88.3) (t = 0.88, P = 0.38), however, the two measures were not significantly correlated (R(s) = 0.04, P=0.82). More validation of the CALUX bioassay with larger sample volume is needed before application as an exposure measure in large-scale epidemiologic studies of health effects of dioxin-like compounds.
机译:多氯二苯并-对-二恶英(PCDD),多氯二苯并呋喃(PCDF)和多氯联苯(PCB)是广泛的环境污染物,以复杂混合物的形式存在,在人类中的检出水平通常为万亿分之一(ppt)。我们使用同位素稀释高分辨率气相色谱/高分辨率质谱法(HRGC / HRMS),对居住在意大利塞维索附近发生TCDD爆炸的78名妇女的血清中的PCDDs,PCDFs和PCBs进行了测量。 1976年开始生产家具。这些妇女经脂质调整后的平均总二恶英样毒性当量(TEQ)为25.3 ppt,与欧洲其他地区相当。但是,在1976年居住在裸露地区的少数妇女中,TCDD水平较高。我们研究了使用CALUX(化学激活的荧光素酶基因表达)生物测定法评估该人群中少量血浆中总TEQ的可能性。 。根据HRGC / HRMS的总TEQ分布,总共选择了32个存档血浆样本进行CALUX生物测定。 CALUX生物测定法不符合HRGC / HRMS结果,每次重复分析使用2 ml血浆。在32个样品中,有10个样品低于CALUX生物测定法中的检出限。对于这32个样品,经脂质调整的CALUX-TEQ平均为25.4 ppt(范围:0-127.6),与经脂质调整的HRGC / HRMS总TEQ平均为31.2 ppt(范围:12.7-88.3)没有显着差异。 (t = 0.88,P = 0.38),但是,这两个指标之间没有显着相关性(R(s)= 0.04,P = 0.82)。在将二恶英样化合物对健康的影响进行大规模流行病学研究之前,需要在更大样本量下对CALUX生物测定法进行更多的验证,以作为一种暴露措施。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号