首页> 外文期刊>Journal of engineering thermophysics >Sustainable energy development in power generation by using green inlet-air cooling technologies with gas turbine engines
【24h】

Sustainable energy development in power generation by using green inlet-air cooling technologies with gas turbine engines

机译:通过将绿色进气冷却技术与燃气轮机结合使用,实现发电领域的可持续能源开发

获取原文
获取原文并翻译 | 示例
           

摘要

This paper studies the different greening techniques of inlet air cooling and compares their effects on performance, especially power, efficiency, fuel consumption, and condensable water. A comparison between four air cooling techniques, namely, mechanical chillers, absorption chillers, evaporative cooling and fogging systems was performed on a gas turbine. The performance characteristics were examined for a set of design and operational variables including ambient temperature, relative humidity, compressor pressure ratio, and turbine inlet temperature. The absorption chiller is a single-stage vapor absorption refrigeration system using water-lithium bromide (H2O/LiBr) as the working fluid, where the generator and the absorber have fixed temperatures with variation in the heat load (evaporative cooling load) that produces the gas turbine inlet air temperature value of 5A degrees C. The analysis showed that the evaporative cooling enhanced the power by up to 8.7% and efficiency by up to 3.3%. On the other hand, the fogging system enhanced the power by up to 9.5% and the efficiency by up to 3.5%. The mechanical chiller reduced the temperature by 20 to 45A degrees C; enhancing the net power by 7 to 24.3% and improving the efficiency by 2.4 to 18.8%, whereas the absorption chillers enhanced the net power by up to 12.1 to 37.3% and improved the efficiency by up to 31.5%.
机译:本文研究了进气冷却的不同绿化技术,并比较了它们对性能的影响,尤其是功率,效率,燃料消耗和可冷凝水。在燃气轮机上对四种空气冷却技术(即机械冷却器,吸收式冷却器,蒸发冷却和雾化系统)进行了比较。检查了一组设计和运行变量的性能特征,包括环境温度,相对湿度,压缩机压力比和涡轮进口温度。吸收式冷却器是一种单级蒸气吸收式制冷系统,使用水-溴化锂(H2O / LiBr)作为工作流体,其中发生器和吸收器的温度固定,并且热负荷(蒸发冷却负荷)变化。燃气轮机进气温度为5A摄氏度。分析表明,蒸发冷却使功率提高了8.7%,效率提高了3.3%。另一方面,雾化系统将功率提高了9.5%,效率提高了3.5%。机械冷却器将温度降低了20至45A摄氏度;将净功率提高了7至24.3%,将效率提高了2.4至18.8%,而吸收式制冷机将净功率提高了12.1至37.3%,将效率提高了31.5%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号