首页> 外文期刊>Journal of endovascular therapy: an official journal of the International Society of Endovascular Specialists >Impact of the Rapid-Exchange Versus Over-the-Wire Technique on Procedural Complications of Renal Artery Angioplasty.
【24h】

Impact of the Rapid-Exchange Versus Over-the-Wire Technique on Procedural Complications of Renal Artery Angioplasty.

机译:快速交换与无线技术对肾动脉血管成形术程序并发症的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: To investigate whether the use of rapid-exchange (RX) systems adds to the safety of percutaneous renal artery procedures compared to the conventional over-the-wire (OTW) technique.Methods: The interventional registry in our department was interrogated to identify patients who underwent plain balloon angioplasty and/or stent implantation for >60% renal artery stenosis and intractable hypertension or decreasing renal function between 1998 and 2004. In this time period, 63 consecutive patients (36 men; mean age 67 years, range 57-80) underwent 78 renal artery angioplasty procedures. The first 46 procedures were done using a transfemoral OTW technique via 7-F sheaths; the following 32 procedures were performed with an RX system via a transfemoral 6-F access. Duration of fluoroscopy, amount of contrast agent, course of serum creatinine, and complications were compared between OTW and RX approaches.Results: Duration of fluoroscopy (median 13.1 versus 11.1 minutes, p=0.099) and primary technical success (94% versus 97%, p=0.64) were not significantly different between the OTW and RX approaches, but significantly less contrast agent was needed with the RX system (median 215 versus 140 mL, p<0.001). Complications, all minor, occurred significantly more often with the OTW (11/46, 24%) compared to the RX system (2/32, 6%; p=0.040) and included misplaced stents, prolonged severe hyper/hypotension, transient renal impairment, and puncture site complications. In particular, the rates of increased serum creatinine within 24 hours were higher in the OTW patients compared to the RX group (20% versus 3%, respectively, for >25% increase [p=0.041] and 9% versus 0% for >50% increase [p=0.087]).Conclusions: Rapid exchange systems seem to add to the safety of percutaneous renal artery interventions. This likely may be due to a variety of causes, including lower doses of contrast medium, shorter duration of fluoroscopy, and smaller device diameters.
机译:目的:研究与传统的在线(OTW)技术相比,快速交换(RX)系统是否增加了经皮肾动脉手术的安全性。方法:对我科的介入性注册表进行了询问,以确定在1998年至2004年之间接受了大于60%的肾动脉狭窄和顽固性高血压或肾功能下降的患者,进行了单纯球囊血管成形术和/或支架植入的患者。在此期间,连续63例患者(36名男性;平均年龄67岁,范围57- 80)接受了78例肾动脉血管成形术。前46例手术是使用经股OTW技术通过7-F护套完成的;接下来的32个程序是通过股骨6-F通路通过RX系统执行的。比较了OTW和RX方法的荧光检查时间,造影剂的量,血清肌酐的变化过程以及并发症的发生。结果:荧光检查的时间(中位13.1对11.1分钟,p = 0.099)和主要技术成功率(94%对97%) ,p = 0.64)在OTW和RX方法之间没有显着差异,但是RX系统所需的造影剂明显更少(中位数215 vs 140 mL,p <0.001)。与RX系统(2/32,6%; p = 0.040)相比,OTW并发症(11/46,24%)发生的频率明显更高,包括支架放置错误,长时间的严重高/低血压,短暂性肾损伤和穿刺部位并发症。特别是,OTW患者的24小时内血清肌酐增加率高于RX组(增加> 25%分别为20%对3%[p = 0.041], 9%相对为0%[>增加50%[p = 0.087]。)结论:快速更换系统似乎增加了经皮肾动脉介入治疗的安全性。这可能是由于多种原因引起的,包括造影剂剂量较低,荧光检查的持续时间较短以及设备直径较小。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号