首页> 外文期刊>Journal of chromatography, B. Analytical technologies in the biomedical and life sciences >A fast and simple assay for busulfan in serum or plasma by liquid chromatography-tandem mass spectrometry using turbulent flow online extraction technology
【24h】

A fast and simple assay for busulfan in serum or plasma by liquid chromatography-tandem mass spectrometry using turbulent flow online extraction technology

机译:使用湍流在线萃取技术的液相色谱-串联质谱法快速,简单地测定血清或血浆中的白消安

获取原文
获取原文并翻译 | 示例
           

摘要

Busulfan is used in myeloablative preparation regimens for hematopoietic bone marrow transplantation. Due to its narrow therapeutic range therapeutic drug monitoring of busulfan is recommended. In this study a fast and simple method for measuring busulfan in serum or plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed utilizing turbulent flow online extraction technology. Serum or plasma was mixed with acetonitrile containing d_8-busulfan. After centrifugation the supernatant was injected onto a turbulent flow preparatory column then transferred to a C18 analytical column monitored by a tandem mass spectrometer set at positive electrospray ionization. The analytical cycle time was 4.0min. The method was linear from 0.15 to 41.90μmol/L with an accuracy of 87.9-103.0%. Inter- and intra-assay CVs across four concentration levels were 2.1-7.8%. No significant carryover or ion suppression was observed. No interference was observed from commercial control materials containing more than 100 compounds. Comparison with a well established LC-MS/MS method using patient specimens (n=45) showed a mean bias 1.3% with Deming regression of slope 1.02, intercept -0.02μmol/L, and a linear correlation coefficient 0.9883. The LC-MS/MS method coupled with turbulent flow online sample cleaning technology described here offers reliable busulfan quantitation in serum or plasma with minimum manual sample preparation and was fully validated for clinical use.
机译:白消安用于造血骨髓移植的清髓治疗方案中。由于其狭窄的治疗范围,建议对白消安进行治疗药物监测。在这项研究中,利用湍流在线萃取技术开发了一种快速简单的液相色谱-串联质谱法(LC-MS / MS)测定血清或血浆中白消安的方法。将血清或血浆与含有d_8-环丁砜的乙腈混合。离心后,将上清液注射到湍流制备柱上,然后转移到由串联质谱仪监控的C18分析柱上,该串联质谱仪设置为正电喷雾电离。分析循环时间为4.0分钟。该方法在0.15至41.90μmol/ L之间呈线性关系,准确度为87.9-103.0%。跨四个浓度水平的测定间和测定内CV为2.1-7.8%。没有观察到明显的残留或离子抑制。包含100多种化合物的商业对照材料未发现干扰。与使用患者标本(n = 45)建立的LC-MS / MS方法进行的比较显示,平均偏差为1.3%,戴明回归的斜率为1.02,截距为-0.02μmol/ L,线性相关系数为0.9883。此处介绍的LC-MS / MS方法与湍流在线样品清洁技术相结合,可通过最少的手动样品制备就对血清或血浆中的白消安进行可靠的定量,并且已经过临床验证。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号