PURPOSE: To assess the folding and implantation of the single-piece EasAcryl 1 intraocular lens (IOL) and the maintenance of the tunnel structure and capsular bag stability after implantation. SETTING: S. Orsola Hospital Department of Pathophysiologic Optics, University of Bologna, Bologna, Italy. METHODS: This study comprised 300 cases of EasAcryl 1 IOL implantation. First, a 3.2 mm corneal incision was made according to preoperative astigmatism followed by a 5.5 mm +/- 0.3 (SD) capsulorhexis. After sutureless phacoemulsification using a venturi pump, the 6.0 mm optic, 11.0 mm diameter IOL was implanted using a hexagonal cartridge. The IOLs were implanted using a 2-step maneuver when the superior haptic was grasped with the forceps (first case) or a 1-step maneuver when only the Microsert injector was used. The cartridge was never pushed beyond the tunnel. The preoperative and postoperative incision size and the corneal surgically induced astigmatism were recorded. The IOL rotation was measured 30 +/- 5 days and 8 +/- 1 months postoperatively. RESULTS: No intraoperative complications occurred after the learning curve. No alteration in astigmatism was observed. The mean IOL rotation was 1.04 +/- 0.5 degrees at 30 +/- 5 days and 1.02 +/- 0.2 degrees at 8 +/- 1 months. CONCLUSIONS: The EasAcryl 1 was easily implantation through a 3.2 mm tunnel without altering the natural architecture. The unfolding of the IOL was well controlled, and the IOL remained well centered. A short learning curve is required.
机译:目的:评估单片EasAcryl 1人工晶状体(IOL)的折叠和植入,以及植入后隧道结构和囊袋稳定性的维持情况。地点:意大利博洛尼亚博洛尼亚大学S. Orsola医院病理生理光学科。方法:本研究包括300例EasAcryl 1 IOL植入术。首先,根据术前散光进行3.2 mm角膜切口,然后进行5.5 mm +/- 0.3(SD)撕囊。使用文丘里泵进行无缝线超声乳化后,使用六边形筒植入6.0 mm光学元件,直径11.0 mm的IOL。当用镊子握住上时,使用2步法植入IOL(第一种情况),或者仅使用Microsert注射器时使用1步法植入IOL。墨盒从未被推过通道。记录术前和术后切口的大小以及手术引起的角膜散光。术后30 +/- 5天和8 +/- 1个月测量IOL旋转。结果:学习曲线后未发生术中并发症。没有观察到散光的改变。在30 +/- 5天时,平均IOL旋转为1.04 +/- 0.5度,在8 +/- 1个月时为1.02 +/- 0.2度。结论:EasAcryl 1可以很容易地通过3.2 mm隧道植入,而无需改变自然结构。 IOL的展开得到了很好的控制,并且IOL仍然保持居中状态。需要简短的学习曲线。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号