PURPOSE: To perform colorimetric characterization of 2 blue light-filtering intraocular lens (IOL) models and an IOL that filters ultraviolet-violet (UV-v) light and compare the charactizations with those of a standard UV light-filtering IOL and the human crystalline lens at various ages. SETTING: Department of Clinical Physiopathology, University of Florence, and National Institute of Applied Optics, CNR, Florence, Italy. DESIGN: Experimental study. METHODS: Three IOLs of each model with different dioptric powers (16.0, 21.0, and 26.0 diopters) were analyzed. The colorimetric coordinates of the IOLs were calculated by measuring their transmission spectra using a microspectroscopy technique. Subsequently, a parameter (DeltaE) that was proportional to the perceived color differences was defined. The results of the IOLs and of the human crystalline lens at different ages (4, 22, 41, 53, and 72 years; values taken from the literature) were compared. The colorimetric analysis was performed using Commission Internationale de l'Eclairage standards. RESULTS: The maximum DeltaE value was with the standard UV light-filtering IOL at any crystalline lens age and was greatest with a 72-year-old human lens. The minimum DeltaE value was obtained for both blue light-filtering IOLs with middle-aged human lenses. CONCLUSIONS: None of the analyzed IOLs had the same colorimetric performance of the human crystalline lens. The 2 blue light-filtering IOLs best reproduced yellowing of the human lens at 40 to 50 years of age. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
机译:目的:对两种蓝色滤光人工晶状体(IOL)模型和可过滤紫外线(UV-v)的IOL进行比色表征,并将其特征与标准的UV滤光IOL和人类晶体进行比较各个年龄段的镜头。地点:佛罗伦萨大学临床生理病理学系和意大利佛罗伦萨CNR国家应用光学研究所。设计:实验研究。方法:分析了每个模型的三个具有不同屈光度数(16.0、21.0和26.0屈光度)的IOL。通过使用显微光谱技术测量其透射光谱来计算IOL的比色坐标。随后,定义了与感知的色差成正比的参数(DeltaE)。比较了不同年龄(4、22、41、53和72岁;来自文献的值)的IOL和人类晶状体的结果。比色分析是使用国际照明委员会标准进行的。结果:在任何晶状体年龄下,最大DeltaE值均与标准的紫外线滤光IOL有关,而对于72岁的人晶状体而言,最大DeltaE值最大。对于具有中年人类镜片的两种蓝色滤光IOL,均获得了最小DeltaE值。结论:没有分析的IOL比人类晶状体具有相同的比色性能。 2种滤蓝光的IOL可以最好地再现40至50岁时人类晶状体的泛黄。财务披露:没有任何作者对所提及的任何材料或方法有财务或所有权利益。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号