Twin shell type DC arc furnace with scrap preheating system was supplied by Daido to Takunan Steel in Okinawa. This furnace is equipped with one power source and two furnace bodies and also high efficiency scrap preheating function, the advantages, functions and operation results are reported in this paper. The summary of the operation results obtained up to now are as follows; 1) Reduction of tap to tap time by 11 min comparing with single furnace, 2) Improvement of maximum 35kWh/t in electric power consumption by scrap preheating, and 3) Reduction of 18kWh/t through effective utilization of post combustion. It should be noted that these operation figures are under the restriction of electric power source. Therefore, not less than the improvement figures described above are expected when normal electric power is inputted in near future.
机译:大同向冲绳的Takunan Steel提供了带废料预热系统的双壳式直流电弧炉。该炉配有一个电源和两个炉体,还具有高效的废料预热功能,本文报道了其优点,功能和运行结果。到目前为止获得的操作结果总结如下: 1)与单炉相比,将出钢时间缩短了11分钟; 2)通过废料预热将最大耗电量降低了35kWh / t; 3)通过有效利用后燃烧,将耗电量降低了18kWh / t。应该注意的是,这些操作数字受电源的限制。因此,在不久的将来输入正常电力时,期望得到不低于上述的改善数字。