...
首页> 外文期刊>World Journal of Applied Chemistry >Determination of Azelastine Hydrochloride and Benzalkonium Chloride in Their Ophthalmic Solution by Different Spectrophotometric Methods
【24h】

Determination of Azelastine Hydrochloride and Benzalkonium Chloride in Their Ophthalmic Solution by Different Spectrophotometric Methods

机译:分光光度法测定滴眼液中盐酸氮卓斯汀和苯扎氯铵的含量。

获取原文
           

摘要

Three simple, specific, accurate and precise spectrophotometric methods for the determination of a binary mixture of Azelastine hydrochloride (AZH) and Benzalkonium chloride (BAC) in pure and in their Dosage forms. The methods namely; (A) zero order (Dsup0/sup), (B) ratio difference (RD) and (C)ratio subtraction (RS). In method (A), AZH could be directly determined in the zero order at wave length equals to 284 nm in the range (5.0–50 μg/mL) with good correlation coefficient (0.9994), where no interference from BAC is reported. While BAC was determined by different methods in the range (2.0–30 μg/mL). In method (B) BAC determination depends on dividing the spectrum of the binary mixture by the standard spectrum of 20μg/mL AZH as a divisor, then BAC is determined using the difference between the two wavelengths 262 & 208 nm, we here BAC has absorbances and AZH is constant, the difference = (iΔ/iP262.0-208.0) with good correlation coefficient (0.9994). Finally, in method (C) BAC can be determined by dividing the spectrum of the binary mixture by the standard spectrum of 10 μg/mL AZH as a dvisor, then a constant, which is determined as the mean value of the absorbances in the plateau region (230–300 nm), is subtracted; after multiplication by the divisor we obtain a zero order (Dsup0/sup) original spectrum of BAC at 208.0 nm with good correlation coefficient (0.9992). Accuracy, recovery and the selectivity of the developed methods are applied on the laboratory prepared mixtures, standard addition technique and pharmaceutical dosage form. The obtained results for the suggested methods are statistically compared with the reported HPLC one using student’s-t and F-ratio tests, showing that the two methods are accurate and precise.
机译:三种简单,特异,准确和精确的分光光度法测定纯正和剂量形式的盐酸氮卓斯汀(AZH)和苯扎氯铵(BAC)的二元混合物。该方法即; (A)零阶(D 0 ),(B)比率差(RD)和(C)比率减法(RS)。在方法(A)中,在波长等于284 nm的范围内(5.0–50μg/ mL)中,波长为284 nm时,可以以零级直接确定AZH,且相关系数良好(0.9994),没有BAC干扰的报道。而BAC的测定范围为(2.0–30μg/ mL)。在方法(B)中,BAC的确定取决于将二元混合物的光谱除以20μg/ mL AZH的标准光谱作为除数,然后使用两个波长262和208 nm之间的差确定BAC,我们在这里BAC具有吸光度并且AZH为常数,则差=(ΔP262.0-208.0),具有良好的相关系数(0.9994)。最后,在方法(C)中,BAC可以通过将二元混合物的光谱除以10μg/ mL AZH的标准光谱作为除数来确定,然后确定一个常数,该常数被确定为高原中吸光度的平均值减去区域(230-300 nm);通过除数相乘后,我们得到了BAC在208.0 nm处的零阶(D 0 )原始光谱,具有良好的相关系数(0.9992)。所开发方法的准确性,回收率和选择性适用于实验室制备的混合物,标准添加技术和药物剂型。使用Student-t和F比率测试,将建议方法的所得结果与报告的HPLC方法进行统计比较,表明这两种方法是准确而精确的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号