In Y-stenting, stabilization of the first stent may be problematic as in some cases it migrates during second stent insertion. This report evaluates the safety and effectiveness of the technique and presents the long-term results of hybrid, Y-configured, dual stent-assisted coil embolization in the treatment of wide-necked bifurcation aneurysms.We retrospectively evaluated the patients treated endovascularly due to cerebral aneurysms. Twenty patients treated with hybrid Y-stent-assisted coil embolization were enrolled in the study. In hybrid stenting, an open-cell intracranial stent (Neuroform) was used as a first stent to prevent stent migration. A closed-cell stent (Enterprise or Acclino) was used as a second stent and the aneurysm was embolized with coils between the stent struts.In all patients, hybrid Y-stenting and coil embolization were accomplished successfully. No stent migration occurred. Clinically, neither symptomatic neurologic complication nor death was seen. Of 20 wide-necked bifurcation aneurysms, nine were at the basilar tip, while seven were at the middle cerebral artery and three at the anterior communicating artery. In one patient, the aneurysm was at the A2-3 junction of the anterior cerebral artery. One of the patients had a subarachnoid hemorrhage. The mean angiographic follow-up was 25.6 months. No in-stent stenosis was seen in any of the patients and recanalization in only one.Hybrid, Y-configured, dual stent-assisted coil embolization is a safe and effective method in the treatment of wide-necked bifurcation aneurysms to prevent stent migration and aneurysm recanalization, and is a viable alternative to microsurgery.
机译:在Y型支架中,第一支架的稳定性可能会出现问题,因为在某些情况下,它会在第二支架插入过程中迁移。本报告评估了该技术的安全性和有效性,并提出了混合,Y型配置,双支架辅助线圈栓塞术治疗宽颈分叉动脉瘤的长期结果。我们回顾性评估了因脑血管内治疗的患者动脉瘤。该研究纳入了20例接受Y形支架辅助混合线圈栓塞治疗的患者。在混合支架术中,开孔颅内支架(Neuroform)被用作防止支架迁移的第一支架。使用闭孔支架(Enterprise或Acclino)作为第二个支架,在支架支杆之间用线圈栓塞动脉瘤,在所有患者中均成功完成了Y型支架和线圈栓塞的混合治疗。没有发生支架迁移。在临床上,既没有发现症状性神经系统并发症,也没有死亡。在20个宽颈分叉动脉瘤中,有9个位于基底尖端,而7个位于大脑中动脉,而3个位于前交通动脉。一名患者的动脉瘤位于大脑前动脉的A2-3交界处。其中一名患者发生了蛛网膜下腔出血。平均血管造影随访时间为25.6个月。在所有患者中均未发现支架内狭窄,仅在一个患者中出现了再通。混合,Y型配置,双支架辅助线圈栓塞术是治疗宽颈分叉动脉瘤以防止支架迁移和转移的一种安全有效的方法。动脉瘤再通,是显微手术的可行替代方案。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号