摘要

Detecting small amounts of analyte in clinical practice is challenging because of deficiencies in specimen sample availability and unsuitable sampling environments that prevent reliable sampling. Paper-based analytical devices (PADs) have successfully been used to detect ultralow amounts of analyte, and origami-based PADs (O-PADs) offer advantages that may boost the overall potential of PADs in general. In this study, we investigated two potential clinical applications for O-PADs. The first O-PAD we investigated was an origami-based enzyme-linked immunosorbent assay (ELISA) system designed to detect different concentrations of rabbit IgG. This device was designed with four wing structures, each of which acted as a reagent loading zone for pre-loading ELISA reagents, and a central test sample loading zone. Because this device has a low limit of detection (LOD), it may be suitable for detecting IgG levels in tears from patients with a suspected viral infection (such as herpes simplex virus (HSV)). The second O-PAD we investigated was designed to detect paraquat levels to determine potential poisoning. To use this device, we sequentially folded each of two separate reagent zones, one preloaded with NaOH and one preloaded with ascorbic acid (AA), over the central test zone, and added 8 µL of sample that then flowed through each reagent zone and onto the central test zone. The device was then unfolded to read the results on the test zone. The three folded layers of paper provided a moist environment not achievable with conventional paper-based ELISA. Both O-PADs were convenient to use because reagents were preloaded, and results could be observed and analyzed with image analysis software. O-PADs expand the testing capacity of simpler PADs while leveraging their characteristic advantages of convenience, cost, and ease of use, particularly for point-of-care diagnosis.
机译:由于标本样品可用性的不足以及不合适的采样环境会妨碍可靠的采样,因此在临床实践中检测少量分析物具有挑战性。纸基分析设备(PAD)已成功用于检测超低含量的分析物,而折纸纸PAD(O-PADs)提供的优势通常可提高PAD的整体潜力。在这项研究中,我们调查了O-PAD的两种潜在临床应用。我们研究的第一个O-PAD是基于折纸的酶联免疫吸附测定(ELISA)系统,旨在检测不同浓度的兔IgG。该设备设计有四个机翼结构,每个机翼结构均用作预加载ELISA试剂的试剂加载区和中央测试样品加载区。由于此设备的检测限(LOD)较低,因此可能适合检测疑似病毒感染(例如单纯疱疹病毒(HSV))患者的眼泪中的IgG水平。我们调查的第二个O-PAD旨在检测百草枯水平以确定潜在的中毒情况。要使用此设备,我们依次将两个单独的试剂区折叠在一起,其中一个预装了NaOH,一个预装了抗坏血酸(AA),在中央测试区上,然后加入8 µL样品,然后流过每个试剂区并进入中央测试区。然后将设备展开以在测试区域上读取结果。纸的三层折叠提供了常规纸基ELISA无法实现的潮湿环境。两种O-PAD都方便使用,因为试剂已预装,并且可以使用图像分析软件观察和分析结果。 O-PAD扩展了简单PAD的测试能力,同时利用了其便利性,成本和易用性(尤其是即时诊断)的独特优势。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号