This paper describes the test results on the direct shear behavior of glass-fiber reinforced polymer (GFRP) shear tie reinforced interfaces between precast concrete sandwich panels (PCSP) and extruded polystyrene (XPS) insulations. The insulated PCSP consists of two concrete panels with 100 mm or 80 mm thick insulation between inner/outer concrete panel layers. In order to achieve composite action concrete panels are connected by corrugated GFRP shear connector. In this study, three types of couple replicate insulated PCSP with different embedment length of GFRP shear connector were made and loaded in push-out. The test results indicated that the reinforcement of GFRP shear ties for interface between PCSP and XPS insulation improves initial and post-peak shear performance of insulated PCSPs. These phenomena are remarkable for XPS insulated PCSPs with larger embedment length of GFRP shear connectors.
机译:本文介绍了对玻璃纤维增​​强聚合物(GFRP)剪切粘结的直接剪切行为的试验结果,Photic混凝土夹层板(PCSP)和挤出的聚苯乙烯(XPS)绝缘之间的增强界面。绝缘PCSP由两个混凝土板组成,内/外混凝土板层之间具有100毫米或80毫米厚的绝缘层。为了实现复合动作,混凝土板通过波纹GFRP剪切连接器连接。在本研究中,制造并在推出中进行了三种类型的耦合复制绝缘PCSP,并加载了GFRP剪切连接器的不同嵌入长度。测试结果表明,PCSP与XPS绝缘之间的接口GFRP剪切领域的加强提高了绝缘PCSP的初始和后峰值剪切性能。这些现象对于具有GFRP剪切连接器的较大嵌入长度的XPS绝缘PCSP是显着的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号