首页> 外文会议>空気清浄とコンタミネーションコントロール研究大会 >A Study on Tests and Evaluation Methods of Odorant Removal Performance for a Urinal Toilet Unit with Deodorization Devices (Part 3), An Investigation of Odorant Emissions in the Toilet Space
【24h】

A Study on Tests and Evaluation Methods of Odorant Removal Performance for a Urinal Toilet Unit with Deodorization Devices (Part 3), An Investigation of Odorant Emissions in the Toilet Space

机译:除臭装置(第3部分)对小便斗机厕所单元的试验和评价方法研究,厕所空间中的气味排放研究

获取原文

摘要

The purpose of the present study is to estalish an evaluation method for a toilet unit with an air cleaning device, and then to investigate the proposed evaluation method by using a field survey. Odorant concentration in the restroom decreases with ventilations, an odor measuring instrument chamber was installed around a urinal toilet stall. The background ammonia concentration was ranged from 0[ppm] to 1446 [ppm] with urination acts, The background Methyl mercaptane was ranged from 0[ppm] to 0.0081 [ppm]. These results can be served as reference information for modeling indoor odorants released from human wastes in the toilets.
机译:本研究的目的是利用空气清洁装置对马桶单元进行评估方法,然后通过使用现场调查来研究所提出的评估方法。洗手间中的气味浓度随通风而降低,气味测量仪器室围绕小便厕所摊位。背景氨浓度为尿作用作用的0 [ppm]至1446 [ppm],背景甲基巯基含量为0 [ppm]至0.0081 [ppm]。这些结果可以作为参考信息,用于建模从厕所中的人类废物中释放的室内气味。