Based on the thermodynamic test data, a new method about online monitoring centrifugal fan performance parameters in power plant is provided, which only measure the signals of static pressure difference between the entrance and exit of fans. Moreover, this paper previews applying this method to establishing the Fan Operating Information Systems (FOIS).