Buildings energy consumption accounts for almost a half of the world energy consumption representing one third of the annual greenhouse gas emissions. Half of the buildings count for the residential sector of witch domestic hot water heating represents 30% of the total energy use. Two typical principles for hot tap water preparation were analyzed: direct preparation using heat exchangers and using storage tanks for accumulation of domestic hot water. The aim of the study is to investigate the need of a storage tank in district heating systems by analyzing the DHW demand distribution throughout the day. Measured per capita daily DHW demand indicate a value of 45 liters compared to design norm that range from 70 to 110 liters per person and day. Measured daily distribution throughout the day has o more balanced distribution compared to design norms recommendation.
机译:建筑物能耗占世界能源消耗的近一半代表年度温室气体排放量的三分之一。一半的建筑物占巫婆国内热水加热的住宅部门代表了总能源使用的30%。分析了热自来水制剂的两个典型原理:使用热交换器直接制备,并使用储罐进行国内热水的积累。该研究的目的是通过分析全天的DHW需求分布,调查地区供热系统中的储罐的需求。每人每日测量的每日DHW需求指示与设计规范相比,值为45升,范围为每人70至110升。与设计规范建议相比,全天的每日分布更加平衡。