首页> 外文会议>International Symposium on Heat Transfer Enhancement and Energy Conservation >A STUDY OF COUPLED CONVECTTVE HEAT AND MASS TRANSFER FROM THIN WATER FILM TO MOIST AIR FLOW
【24h】

A STUDY OF COUPLED CONVECTTVE HEAT AND MASS TRANSFER FROM THIN WATER FILM TO MOIST AIR FLOW

机译:薄水膜与湿气流动耦合耦合热量和质量转移的研究

获取原文

摘要

Convective evaporation of a thin water film is numerically studied to investigate the characteristics of friction, heat, and mass transfer in a laminar boundary-layer flow, A special attention has been paid to the problem of inversion vapor concentration. In the range of T_0= 300-350 K and C_0= 0-0.2, the skin friction at the interface performs without too much change comparing to the flat boundary flow of single phase. On the other hand, the sensible heat transfer and the mass transfer at the interface degrade obviously. 11 % of degradation of sensible heat transfer is shown in the parameter range of the study. An inversion concentration is revealed in the numerical results. Below and above this inversion concentration the latent heat transfer changes with the temperature of free stream in opposite ways.
机译:在数值上研究了薄水膜的对流蒸发,以研究层状边界层流动中摩擦,热量和传质的特性,对反演蒸气浓度的问题已经支付了特别的注意。在T_0 = 300-350 k和C_0 = 0-0.2的范围内,界面处的皮肤​​摩擦在没有过多的变化的情况下比较单相的平坦边界流。另一方面,显而易见的传热和界面处的质量传递显着降低。在该研究的参数范围内显示了合理的传热降解的11%。在数值结果中揭示了反演浓度。低于此反转浓度,潜伏的传热随着自由流的温度以相反的方式变化。