首页> 外文会议>International conferenc on rare earth development and applications >Determination of Trace Rare-Earth Elements of Adult Human Viscera by Inductively Coupled Plasma Mass Spectrometry
【24h】

Determination of Trace Rare-Earth Elements of Adult Human Viscera by Inductively Coupled Plasma Mass Spectrometry

机译:电感耦合等离子体质谱法测定成人内脏中的痕量稀土元素

获取原文

摘要

Inductively Coupled Plasma Mass Spectrometry (ICP-MS)is a new tech-nology in the field of inorganic analysis. It has the advatages of quickness, high sensitivity, simplicity of spectra and capability of simultaneous qualitative and quantitative analysis of multi-elements (including isotopes) in one sample. This paper describes study of trace rare-earth elements of adult human viscera by ICP- MS, selection of optimun instrument parameters and examination of factors causing interferences and effects. Re is used as an internal standard element to compensate for matrix inhibition effect and sensitivity drift. Detection limits for 15 rare-earth elements are 0.005-0.026ng/ml. Recoveries of standard addition are 92.9-111.3%. Relative standard deviations are 0.96-3.07%. On the basis of strict quality control samples of adult human lung, heart, liver, spleen, kidney and muscle are digested by mixed acid ( HNO_3+HClO_3) and measured directly for 15 rare- earth elements without separation and enrichment procedures.
机译:电感耦合等离子体质谱法(ICP-MS)是无机分析领域中的一种新技术。它具有快速,灵敏,光谱简单以及同时定性和定量分析多种样品(包括同位素)的能力。本文介绍了通过ICP-MS研究成人内脏中微量稀土元素的方法,最佳仪器参数的选择以及引起干扰和影响的因素的检查。 Re用作内标元素,以补偿基质抑制作用和灵敏度漂移。 15种稀土元素的检出限为0.005-0.026ng / ml。标准添加物的回收率为92.9-111.3%。相对标准偏差为0.96-3.07%。在严格的质量控制基础上,用混合酸(HNO_3 + HClO_3)消化成人肺,心脏,肝脏,脾脏,肾脏和肌肉的样品,无需分离和富集程序即可直接测量15种稀土元素。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有