Analysis of air concentration in a physical model of the bottom of a spillway chute with aerators

机译:带有曝气器的溢洪道底部的物理模型中的空气浓度分析

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Given the inherent difficulties and constraints of taking measurements on a prototype and representing the behavior of air in a physical model, this paper presents comparative analysis results from air content measurements in a spillway bottom model with aerators. This was done using model measurements and an analytical model to define the accuracy and credibility of extrapolating results to the prototype. The numerical criterion used allows calculation of air concentration decay along the chute at the same point where the physical model measurements were made. Since air concentration can only be measured at the bottom of the prototype, it can be concluded that the analytical approach works well, and with some adjustments, the results can be extrapolated to measure other points on the prototype Air content at the bottom chute is the most important understanding for the protection spillway.
机译:考虑到在原型上进行测量并在物理模型中表示空气行为的固有困难和约束,​​本文介绍了在带有曝气器的溢洪道底部模型中空气含量测量的比较分析结果。这是通过使用模型测量和分析模型来定义将结果外推到原型的准确性和可信度来完成的。所使用的数字标准允许计算在进行物理模型测量的同一点沿斜道的空气浓度衰减。由于只能在原型机的底部测量空气浓度,因此可以得出结论,分析方法效果很好,并且经过一些调整,可以推断出结果以测量原型机上的其他点。对保护溢洪道的最重要的了解。