...
首页> 外文期刊>Physics in medicine and biology. >MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging
【24h】

MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging

机译:MicroPET II:用于小动物成像的改进型microPET扫描仪的设计,开发和初期性能

获取原文
获取原文并翻译 | 示例
           

摘要

MicroPET II is a second-generation animal PET scanner designed for high-resolution imaging of small laboratory rodents. The system consists of 90 scintillation detector modules arranged in three contiguous axial rings with a ring diameter of 16.0 cm and an axial length of 4.9 cm. Each detector module consists of a 14 * 14 array of lutetium oxyorthosilicate (LSO) crystals coupled to a multi-channel photomultiplier tube (MC-PMT) through a coherent optical fibre bundle. Each LSO crystal element measures 0.975 mm * 0.975 mm in cross section by 12.5 mm in length. A barium sulphate reflector material was used between LSO elements leading to a detector pitch of 1.15 mm in both axial and transverse directions. Fused optical fibre bundles were made from 90 μm diameter glass fibres with a numerical aperture of 0.56. Interstitial extramural absorber was added between the fibres to reduce optical cross talk. A charge-division readout circuit was implemented on printed circuit boards to decode the 196 crystals in each array from the outputs of the 64 anode signals of the MC-PMT. Electronics from Concorde Microsystems Inc. (Knoxville, TN) were used for signal amplification, digitization, event qualification, coincidence processing and data capture. Coincidence data were passed to a host PC that recorded events in list mode. Following acquisition, data were sorted into sinograms and reconstructed using Fourier rebinning and filtered backprojection algorithms. Basic evaluation of the system has been completed. The absolute sensitivity of the microPET II scanner was 2.26% at the centre of the field of view (CFOV) for an energy window of 250-750 keV and a timing window of 10 ns. The intrinsic spatial resolution of the detectors in the system averaged 1.21 mm full width at half maximum (FWHM) when measured with a ~(22)Na point source 0.5 mm in diameter. Reconstructed image resolution ranged from 0.83 mm FWHM at the CFOV to 1.47 mm FWHM in the radial direction, 1.17 mm FWHM in the tangential direction and 1.42 mm FWHM in the axial direction at 1 cm offset from the CFOV. These values represent highly significant improvements over our earlier microPET scanner (approximately fourfold sensitivity increase and 25-35% improvement in linear spatial resolution under equivalent operating conditions) and are expected to be further improved when the system is fully optimized.
机译:MicroPET II是第二代动物PET扫描仪,旨在对小型实验室啮齿动物进行高分辨率成像。该系统由90个闪烁检测器模块组成,这些模块布置在三个连续的轴向环中,环的直径为16.0 cm,轴向长度为4.9 cm。每个检测器模块由14 * 14的原硅酸((LSO)晶体阵列组成,这些晶体通过相干光纤束耦合到多通道光电倍增管(MC-PMT)。每个LSO晶体元件的横截面均为0.975毫米* 0.975毫米,长度为12.5毫米。在LSO元件之间使用了硫酸钡反射器材料,导致轴向和横向的探测器间距均为1.15 mm。熔融光纤束由直径为90微米的玻璃纤维制成,数值孔径为0.56。在纤维之间添加间隙壁外吸收剂以减少光学串扰。在印刷电路板上实施了电荷分割读出电路,以从MC-PMT的64个阳极信号的输出中解码每个阵列中的196个晶体。 Concorde Microsystems Inc.(田纳西州诺克斯维尔)的电子产品被用于信号放大,数字化,事件确认,重合处理和数据捕获。符合性数据传递到以列表模式记录事件的主机PC。采集后,将数据分类为正弦图,并使用傅里叶重结合和滤波反投影算法进行重建。系统的基本评估已完成。对于250-750 keV的能量窗口和10 ns的计时窗口,microPET II扫描仪的绝对灵敏度在视场中心(CFOV)为2.26%。当使用直径为0.5毫米的〜(22)Na点源进行测量时,系统中探测器的固有空间分辨率平均为半峰全宽1.21毫米(FWHM)。重建的图像分辨率在CFOV处为0.83 mm FWHM,在径向上为1.47 mm FWHM,在切向为1.17 mm FWHM,在轴向上为1.42 mm FWHM,与CFOV偏移1 cm。这些值代表了与我们早期的microPET扫描仪相比的重大改进(在相同的工作条件下,灵敏度提高了大约四倍,线性空间分辨率提高了25-35%),并且当系统完全优化时,有望进一步提高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号