STUDY DESIGN: This study was conducted to evaluate an anterior cervical fusion plate system, the Orion locking plate, regarding its surgical handling, hardware-related failures, and short-term and long-term results. OBJECTIVES: A comprehensive evaluation of the implant in a broad range of patients with cervical spine diseases. SUMMARY OF BACKGROUND DATA: Locking plates are the most recent devices for achieving anterior cervical spinal fusion and offer considerable advantages such as faster and easier implantation and fewer implant-related failures than older plate systems. METHODS: Ninety-six patients were investigated. All underwent anterior cervical plate fusion as a component of the surgical treatment for symptomatic degenerative cervical spinal disease or for vertebral destruction caused by trauma, tumor, or inflammation. Besides plate fixation, 6 of the 96 patients had a combined ventrodorsal fusion. In 28 cases, one or more vertebral bodies were removed and replaced with titanium place-holders. The remaining 62 patients were first treated by intervertebral inlay placement, and the fused segments were subsequently plated. Neurologic signs and symptoms were evaluated before and after surgery and during a follow-up period of at least 1 year. RESULTS: The rate of neurologic improvement was highest in radiculopathy patients and lowest in patients with severe myelopathy. In all cases, control radiographs demonstrated a solid bony fusion. Clinical deterioration after surgery was seen in four cases of severe myelopathy in which considerable neurologic deficits existed before surgery, possible because of rapid decompression of the cord and associated microvascular alterations. In two of these cases, there was long-term improvement. Additional general complications caused by surgical retraction included temporary swallowing disturbance in seven patients and a large wound hematoma in one. Hardware failures were encountered in three cases, all of them caused by improper implantation technique and not material failure, per se. CONCLUSION: In the study group, the Orion locking plate was easy to use, failure-free if properly implanted, safe for the patient and supported solid bony fusion in every case.
机译:研究设计:本研究旨在评估前颈椎融合板系统Orion锁定板的手术处理,与硬件相关的故障以及短期和长期结果。目的:对广泛的颈椎病患者的植入物进行综合评估。背景技术概述:锁定板是用于实现颈前路脊柱融合术的最新设备,并且比起较旧的板系统,其具有相当大的优势,例如更快,更容易植入,以及与植入物相关的故障更少。方法:对96例患者进行了调查。所有患者均接受了颈椎前路钢板融合术,作为有症状的退行性颈椎病或因外伤,肿瘤或炎症引起的椎体破坏的外科手术治疗的一部分。除钢板固定外,96例患者中有6例合并了腹背融合。在28例病例中,一个或多个椎体被切除,并用钛合金占位器代替。其余的62例患者首先接受椎间隙镶嵌术治疗,然后将融合节段镀敷。在手术前后以及至少一年的随访期间评估神经系统的体征和症状。结果:神经系统疾病改善率在神经根病患者中最高,在严重脊髓病患者中最低。在所有情况下,对照X光片均显示出牢固的骨融合。在四例严重的脊髓病中观察到手术后的临床恶化,其中在手术前存在相当大的神经功能缺损,这可能是由于脐带快速减压和相关的微血管改变所致。在其中两种情况下,可以长期改善。由手术牵开引起的其他一般并发症包括7例患者的临时吞咽障碍和1例较大的伤口血肿。在三种情况下遇到了硬件故障,它们都是由不正确的植入技术引起的,而不是材料故障本身。结论:在研究组中,Orion锁定板易于使用,正确植入后不会出现故障,对患者安全并且在每种情况下均支持固体骨融合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号