OBJECTIVE: The purpose of this prospective study was to investigate the practicality, accuracy, and reliability of upright MR imaging as a new radiation-free technique for the measurement of mechanical axis. METHODS: We used upright MRI in 15 consecutive patients (30 limbs, 44.7 +/- 20.6 years old) to measure mechanical axis deviation (MAD), hip-knee-ankle (HKA) angle, leg length, and all remaining angles of the frontal plane alignment according to Paley (mLPFA, mLDTA, mMPTA, mLDTA, JLCA). The measurements were compared to weight bearing full length radiographs, which are considered to be the standard of reference for planning corrective surgery. FDA-approved medical planning software (MediCAD) was used for the above measurements. Intra- and inter-observer reproducibility using mean absolute differences was also calculated for both methods. RESULTS: The correlation coefficient between angles determined with upright MRI and weight bearing full length radiographs was high for mLPFA, mLDTA, mMPTA, mLDTA, and the HKA angle (r > 0.70). Mean interobserver and intraobserver agreements for upright MRI were also very high (r > 0.89). The leg length and the MAD were significantly underestimated by MRI (-3.2 +/- 2.2 cm, p < 0.001 and -6.2 +/- 4.4 mm, p = 0.006, respectively). CONCLUSIONS: With the exception of underestimation of leg length and MAD, upright MR imaging measurements of the frontal plane angles are precise and produce reliable, reproducible results.
机译:目的:本前瞻性研究的目的是研究立式MR成像的实用性,准确性和可靠性,作为一种新的无辐射技术来测量机械轴。方法:我们对15例连续患者(30肢,44.7 +/- 20.6岁)进行了直立MRI检查,以测量机械轴偏斜(MAD),髋膝踝(HKA)角度,腿长以及所有剩余角度根据Paley(mLPFA,mLDTA,mMPTA,mLDTA,JLCA)进行额面对齐。将测量结果与承重全长X射线照片进行比较,这些照片被认为是规划矫正手术的参考标准。上述测量使用了FDA批准的医疗计划软件(MediCAD)。两种方法均使用平均绝对差计算观察者之间和观察者之间的可重复性。结果:对于mLPFA,mLDTA,mMPTA,mLDTA和HKA角,通过立式MRI确定的角度与负重全长X线照片之间的相关系数较高(r> 0.70)。直立MRI的平均观察者间和观察者内一致性也很高(r> 0.89)。 MRI显着低估了腿的长度和MAD(分别为-3.2 +/- 2.2 cm,p <0.001和-6.2 +/- 4.4 mm,p = 0.006)。结论:除了低估了腿长和MAD以外,额面角度的直立MR成像测量非常精确,并且可以得出可靠,可重复的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号