首页> 外文期刊>Sensors and Actuators, A. Physical >A device for measurements of the temperature response to single discharges with high local resolution and fast response time
【24h】

A device for measurements of the temperature response to single discharges with high local resolution and fast response time

机译:一种具有高局部分辨率和快速响应时间的单次放电温度响应测量装置

获取原文
获取原文并翻译 | 示例
           

摘要

We report on a thermal device consisting of 14 thin film Au-Pd thermocouples designed to measure the transient temperature response of a sample (a thin 50 mum thick steel foil) submitted to a single discharge. Junctions as small as 4 mum(2) were patterned using standard photolithography. The distance between the junctions (i.e. the local resolution of the device) is 20 mum. Using standard electron discharge machining (EDM) equipment, the temperature response due to a single discharge was measured. The maximum measured temperature was 280 degreesC for a thermocouple located on the backside of the steel foil at 61 mum from the center of the discharge. Large temperature gradients of 2.5 x 10(6) degreesC/m and quench rates of 5 x 10(5) degreesC/s have been measured. Analysis of the thermovoltage noise pattern allowed precise determination of the beginning and duration of the discharge. Preliminary results of the numerical calculations are given. 0, 2004 Elsevier B.V. All rights reserved.
机译:我们报告了一种由14个薄膜Au-Pd热电偶组成的热装置,该热电偶旨在测量一次放电后样品(50毫米厚的薄钢箔)的瞬态温度响应。使用标准光刻对小至4 mum(2)的结进行构图。结点之间的距离(即设备的本地分辨率)为20微米。使用标准的电子放电加工(EDM)设备,测量由于一次放电引起的温度响应。位于钢箔背面的热电偶的最高测量温度为280摄氏度,距离放电中心61毫米。已测得2.5 x 10(6)摄氏度/米的大温度梯度和5 x 10(5)摄氏度/秒的淬火速率。通过分析热电压噪声模式,可以精确确定放电的开始和持续时间。给出了数值计算的初步结果。 2004年9月0日,Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号